{"product_id":"ds200ddtbg2a-ge-ls2100-auxiliary-i-o-terminal-board","title":"DS200DDTBG2A GE LS2100 Auxiliary I\/O Terminal Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE DS200DDTBG2A (DS200DDTBG2A)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary Auxiliary I\/O Terminal Board for the GE LS2100 Static Starter Control system. This board provides the physical termination points for external field wiring, facilitating the exchange of discrete and analog signals between the static starter and the broader plant control network. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment. The DS200DDTBG2A acts as a critical interface for monitoring system status and executing auxiliary control functions, such as blower motor starts, enclosure temperature monitoring, and breaker position feedback. By centralizing these connections, the board ensures organized, secure, and electrically stable signal routing for heavy-duty gas turbine starting applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe DS200DDTBG2A utilizes a ruggedized hardware layout to manage high-density field wiring and signal conditioning.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDS200DDTBG2A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLS2100 Static Starter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple Discrete Inputs and Relay Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFixed screw-type barrier terminal blocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-density ribbon cable headers for DSP\/Control connection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOnboard surge suppression and circuit filtering\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN-rail or standoff mounting within LS2100 cabinet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe DS200DDTBG2A addresses the unique demands of high-power static starter environments through specialized engineering:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE engineers optimized the DS200DDTBG2A to operate in proximity to high-power SCR (Silicon Controlled Rectifier) bridges. Onboard capacitors and filtering networks neutralize electromagnetic interference (EMI), preventing electrical noise from causing false signal triggers in the control logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Torque Secure Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board features industrial-grade barrier terminal blocks designed for heavy-duty field wiring. These terminals resist loosening caused by the mechanical vibrations inherent in turbine enclosures, ensuring continuous electrical contact for critical feedback loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe architecture incorporates optical isolators for discrete input channels. This protects the sensitive digital signal processors (DSPs) in the LS2100 from high-voltage transients or ground faults occurring in the external field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Diagnostic Access:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClearly labeled terminal points and dedicated test headers allow technicians to measure I\/O voltages directly at the board face. This design streamlines the troubleshooting process, enabling rapid identification of external wiring faults versus internal control issues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the DS200DDTBG2A interface with the main control core?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe board connects to the DSPC or similar control processors via high-density ribbon cables. These cables carry conditioned I\/O data from the field terminals to the digital logic backplane. Ensure the locking tabs on these headers are fully engaged during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DS200DDTBG2A replace a G1A revision?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe G2A revision typically offers enhanced component ratings and updated circuit protection. While functionally similar, you must verify your specific LS2100 wiring diagram and software configuration to ensure full compatibility with the G2A hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat maintenance does this terminal board require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaintenance involves periodic visual inspections for terminal discoloration (indicating overheating) and verifying the tightness of all screw connections. In high-vibration environments, GE recommends annual torque checks on all field wiring terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this board support 125 VDC discrete inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the DS200DDTBG2A can manage various voltage levels depending on the jumper settings and excitation source. Always refer to the site-specific elementary drawings to confirm the correct wetting voltage for your specific I\/O configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53463787897016,"sku":"DS200DDTBG2A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/DS200DDTBG2A_3_1.jpg?v=1778745982","url":"https:\/\/www.globalpetroparts.com\/products\/ds200ddtbg2a-ge-ls2100-auxiliary-i-o-terminal-board","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}