{"product_id":"ds200ldcch1ama-ge-mark-v-drive-control-and-lan-communications-board","title":"DS200LDCCH1AMA GE Mark V Drive Control and LAN Communications Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE DS200LDCCH1AMA (DS200LDCCH1A)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as the primary computational and communications hub for the GE Mark V Drive and Turbine Control system. This board integrates two critical functions: high-speed drive control logic and Local Area Network (LAN) management via ARCNET and DLAN protocols. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control infrastructure utilizes the highest grade components available. By centralizing the operator interface communications and core drive processing, the DS200LDCCH1AMA ensures deterministic performance and synchronized data flow across the entire control network.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDS200LDCCH1AMA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark V \/ Innovation Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBoard Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDrive Control and LAN Communications (LDCCH)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMicroprocessors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-processor architecture (LAN, Control, and Co-processors)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eARCNET, DLAN (Drive LAN), RS-232 Serial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVisual Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1-line Alphanumeric LED Status Display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C (32 to 131 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRevision Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAMA (Latest Hardware Revision)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe DS200LDCCH1AMA resolves complex system integration issues through several advanced engineering features:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDedicated LAN Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA dedicated microprocessor manages all network traffic (ARCNET\/DLAN), preventing communication overhead from slowing down the real-time drive control loops. This ensures that the turbine or motor response remains consistent even during heavy network data requests.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRevision \"AMA\" Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"AMA\" suffix represents the most advanced hardware iteration for this board series. It features optimized power distribution and improved surface-mount components that offer higher resistance to thermal cycling compared to older \"A\" or \"ALA\" versions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Hardware Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe on-board 14-segment LED display provides immediate hardware diagnostics. Engineers can verify initialization sequences and identify specific failure codes without attaching a computer, significantly reducing diagnostic downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInter-Board Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMultiple high-density ribbon connectors facilitate direct communication with the I\/O boards and the Signal Processor (DSPC) board, creating a tightly coupled control environment that minimizes signal latency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Site Migration Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure the longevity of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware, professional installation protocols are mandatory:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEEPROM Transfer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe DS200LDCCH1AMA contains several socketed EEPROM chips. These chips hold your site-specific configuration and application software. You must move these chips from your original board to the new board to maintain existing system logic and drive parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eESD Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-density CMOS components on this board are extremely susceptible to static. Use a grounded anti-static wrist strap throughout the entire handling and installation process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJumper Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore powering up, verify that the hardware jumpers on the new \"AMA\" board match the settings of the board being replaced. Incorrect jumper settings can lead to communication mismatches or improper voltage scaling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the DS200LDCCH1AMA interchangeable with older LDCCH versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \"AMA\" version is the current functional replacement for all previous DS200LDCCH1A series boards. It is fully backward compatible but offers modernized hardware stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the board ship with pre-installed software?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe board hardware is new, but the functional \"intelligence\" resides in the socketed EEPROMs. You must either transfer your existing chips or install new chips programmed with your specific site configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I do if the LED display shows a fault code immediately after installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst, verify that all ribbon cables are seated perfectly. If the error persists, check the jumper settings and ensure the EEPROM chips are oriented correctly in their sockets, as a reversed chip will prevent the board from booting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53452584255672,"sku":"DS200LDCCH1AMA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/DS200LDCCH1AMA_1.jpg?v=1778463709","url":"https:\/\/www.globalpetroparts.com\/products\/ds200ldcch1ama-ge-mark-v-drive-control-and-lan-communications-board","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}