{"product_id":"ds200pccag6acb-ge-mark-v-power-connect-card","title":"DS200PCCAG6ACB | GE | Mark V Power Connect Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe DS200PCCAG6ACB (DS200PCCAG6ACB) serves as a vital Power Connect Card (PCCA) within the General Electric Mark V Speedtronic turbine control framework. This module facilitates the secure distribution of control power and critical signal pathways between the power supply modules and the various functional boards in the control rack. It acts as a centralized junction for voltage regulation and filtering, ensuring that sensitive microprocessors receive clean, stable power. This unit arrives as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and original\u003c\/strong\u003e, providing the pristine copper traces and high-grade connectors necessary to prevent voltage drops and communication jitter in critical power generation environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe DS200PCCAG6ACB features a ruggedized PCB design capable of managing multiple power rails and high-density signal routing.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDS200PCCAG6ACB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark V Speedtronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBoard Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Connect Card (PCCA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Mark V 125 VDC \/ 24 VDC rails\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-density ribbon cable headers and screw terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C (32 to 140 Fahrenheit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95 percent (non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.98 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.0 cm x 15.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCentralized Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe PCCA board organizes complex power routing into a single hardware point, which simplifies cabinet internal architecture and reduces the risk of wiring errors during system maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated filtering components on the DS200PCCAG6ACB suppress high-frequency noise and transients originating from the plant's DC bus, protecting the core processors from electrical interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Reliability Connectors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE utilizes industrial-grade, gold-plated headers to ensure low-resistance connections. These connectors resist oxidation, a major cause of intermittent power faults in legacy control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board layout optimizes heat dissipation for its power distribution traces, preventing localized hotspots even during continuous 24\/7 operation in high-ambient temperature turbine enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Field Guidelines\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore securing the board, inspect the mounting standoffs for proper alignment. Stress on the PCB during installation can cause hairline fractures in the multi-layer copper traces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRibbon Cable Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFirmly seat all ribbon cables and engage the plastic locking clips. In high-vibration environments, loose connectors on the PCCA card frequently cause \"I\/O Communication Failure\" or \"Power Supply Dropout\" alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJumper Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-reference the hardware jumper settings with your unit's original technical manual. The PCCA board may require specific jumper configurations to match the voltage monitoring thresholds of your particular turbine model.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"G6ACB\" revision code signify?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \"G6\" identifies the specific group configuration (Standard Power Connect). The \"ACB\" suffix denotes a later hardware revision that incorporates improved dielectric insulation and updated component specifications, ensuring full backward compatibility with older G6 series slots.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this board be used to troubleshoot \"Low Voltage\" alarms?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. If your system displays persistent low-voltage alarms despite a healthy power source, the PCCA card's filtering capacitors or traces may have aged. Replacing the module with this brand-new unit often restores signal stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is \"hot-swapping\" the DS200PCCAG6ACB permitted?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. You must de-energize the Mark V control core before removing or installing this card. Replacing a power distribution board while energized can cause catastrophic electrical arcs and damage to downstream logic modules.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53455802368184,"sku":"DS200PCCAG6ACB","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/DS200PCCAG6ACB_1.jpg?v=1778570260","url":"https:\/\/www.globalpetroparts.com\/products\/ds200pccag6acb-ge-mark-v-power-connect-card","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}