{"product_id":"eddy-current-signal-converter-con021-pr6424-000-030-emerson-epro","title":"Eddy Current Signal Converter CON021+PR6424\/000-030 Emerson Epro","description":"\u003ch2 data-end=\"291\" data-start=\"271\" data-section-id=\"1n8lizy\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"256\" data-end=\"788\"\u003eThe \u003cstrong data-start=\"260\" data-end=\"285\"\u003eCON021+PR6424\/000-030\u003c\/strong\u003e from Emerson Epro delivers precise signal conversion for industrial displacement monitoring systems.\u003cbr data-start=\"386\" data-end=\"389\"\u003eMoreover, this configuration combines the \u003cstrong data-start=\"431\" data-end=\"441\"\u003eCON021\u003c\/strong\u003e converter with the \u003cstrong data-start=\"461\" data-end=\"479\"\u003ePR6424\/000-030\u003c\/strong\u003e probe and integrated extension cable.\u003cbr data-start=\"517\" data-end=\"520\"\u003eAdditionally, the \u003cstrong data-start=\"538\" data-end=\"563\"\u003eCON021+PR6424\/000-030\u003c\/strong\u003e supports accurate shaft vibration and position monitoring in rotating machinery applications.\u003cbr data-start=\"657\" data-end=\"660\"\u003eTherefore, engineers select this model for reliable performance in turbines, compressors, and high-speed industrial equipment.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCON021+PR6424\/000-030\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEddy Current Signal Converter System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Model\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePR6424\/000-030\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Model\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eNon-contact eddy current sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0 to 4 mm (typical calibrated range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e4 mV\/µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA or dynamic voltage output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eDC to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e≤ ±1% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e≤ 1 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e≤ 0.2% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3.0 m integrated coaxial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eShielded coaxial cable with high EMI resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Probe)\u003c\/td\u003e\n\u003ctd\u003e−35 °C to +180 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Converter)\u003c\/td\u003e\n\u003ctd\u003e−30 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003eM14 × 1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP65 when properly installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e−24 VDC via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.5–0.7 kg total system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eConductive materials such as steel or alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eFactory matched probe, cable, and converter system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Compatibility\u003c\/td\u003e\n\u003ctd\u003ePLC, DCS, and Emerson AMS systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Protection\u003c\/td\u003e\n\u003ctd\u003eHigh resistance to electromagnetic interference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the product new and original?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021+PR6424\/000-030\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis brand new and original from Emerson Epro.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Do you have stock available?\u003c\/strong\u003e\u003cbr\u003eYes, we keep the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021+PR6424\/000-030\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein stock for immediate order fulfillment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How fast can you ship the order?\u003c\/strong\u003e\u003cbr\u003eWe ship within 3 days to 2 weeks depending on order size and inventory availability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Which logistics services do you use?\u003c\/strong\u003e\u003cbr\u003eWe use DHL and other international carriers for fast and secure global delivery services.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What cable length does this model include?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021+PR6424\/000-030\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes a 3 meter integrated cable for flexible installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: What output signals does this system provide?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021+PR6424\/000-030\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides 4–20 mA and dynamic voltage outputs for monitoring systems.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53224517337272,"sku":"CON021+PR6424\/000-030","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/EddyCurrentSignalConverterCON021_PR6424000-000EmersonEpro_3_de7b19a2-3027-4cb2-8bb9-a24f2e7bbec8.jpg?v=1775179782","url":"https:\/\/www.globalpetroparts.com\/products\/eddy-current-signal-converter-con021-pr6424-000-030-emerson-epro","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}