{"product_id":"emerson-deltav-kj3225x1-ba1-rtd-resistance-input-card","title":"Emerson DeltaV KJ3225X1-BA1 RTD \/ Resistance Input Card","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp data-start=\"95\" data-end=\"467\"\u003eThe \u003cstrong data-start=\"89\" data-end=\"105\"\u003eKJ3225X1-BA1\u003c\/strong\u003e RTD \/ resistance input card delivers precise temperature and resistance measurements for Emerson DeltaV M-Series systems.\u003cbr data-start=\"227\" data-end=\"230\"\u003eMoreover, the \u003cstrong data-start=\"244\" data-end=\"260\"\u003eKJ3225X1-BA1\u003c\/strong\u003e supports multiple RTD types and resistance input ranges, ensuring accurate process monitoring.\u003cbr data-start=\"355\" data-end=\"358\"\u003eThis module improves system reliability because it integrates high-precision signal conditioning and fault detection circuitry.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eKJ3225X1-BA1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12P4174X042\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eDeltaV M-Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eRTD \/ Resistance Input Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003eMultiple RTD \/ resistance channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported RTD Types\u003c\/td\u003e\n\u003ctd\u003ePt100, Pt1000, Ni100, custom resistance sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance Range\u003c\/td\u003e\n\u003ctd\u003e0–400 Ω typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1°C for Pt100, typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation Voltage\u003c\/td\u003e\n\u003ctd\u003eLow-level constant current for RTD excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-backplane isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Storage\u003c\/td\u003e\n\u003ctd\u003eInternal capacitors for signal stability and filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eDirect DeltaV backplane connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e130 mm × 60 mm × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eDeltaV carrier mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003ePassive cooling, no fan required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eIndustrial EMC standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003eDesigned for harsh industrial environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"3249\" data-end=\"3368\"\u003e\u003cstrong data-start=\"3249\" data-end=\"3300\"\u003eQ1: Is the KJ3225X1-BA1 original and brand new?\u003c\/strong\u003e\u003cbr data-start=\"3300\" data-end=\"3303\"\u003eA1: Yes, all units are brand new, original, and factory sealed.\u003c\/p\u003e\n\u003cp data-start=\"3370\" data-end=\"3485\"\u003e\u003cstrong data-start=\"3370\" data-end=\"3416\"\u003eQ2: Do you have the KJ3225X1-BA1 in stock?\u003c\/strong\u003e\u003cbr data-start=\"3416\" data-end=\"3419\"\u003eA2: Yes, we have stock available for immediate order processing.\u003c\/p\u003e\n\u003cp data-start=\"3487\" data-end=\"3600\"\u003e\u003cstrong data-start=\"3487\" data-end=\"3534\"\u003eQ3: How fast can you ship the KJ3225X1-BA1?\u003c\/strong\u003e\u003cbr data-start=\"3534\" data-end=\"3537\"\u003eA3: We ship within 3 days to 2 weeks depending on order size.\u003c\/p\u003e\n\u003cp data-start=\"3602\" data-end=\"3719\"\u003e\u003cstrong data-start=\"3602\" data-end=\"3646\"\u003eQ4: Which logistics services do you use?\u003c\/strong\u003e\u003cbr data-start=\"3646\" data-end=\"3649\"\u003eA4: We commonly use reliable carriers such as DHL for fast delivery.\u003c\/p\u003e\n\u003cp data-start=\"3721\" data-end=\"3841\"\u003e\u003cstrong data-start=\"3721\" data-end=\"3768\"\u003eQ5: What RTD types does the module support?\u003c\/strong\u003e\u003cbr data-start=\"3768\" data-end=\"3771\"\u003eA5: It supports Pt100, Pt1000, Ni100, and custom resistance sensors.\u003c\/p\u003e\n\u003cp data-start=\"3843\" data-end=\"3955\"\u003e\u003cstrong data-start=\"3843\" data-end=\"3884\"\u003eQ6: What is the measurement accuracy?\u003c\/strong\u003e\u003cbr data-start=\"3884\" data-end=\"3887\"\u003eA6: The module provides ±0.1°C typical accuracy for Pt100 sensors.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53084317909176,"sku":"KJ3225X1-BA1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/EmersonDeltaVKJ3225X1-BA1RTDResistanceInputCard_1.jpg?v=1774320706","url":"https:\/\/www.globalpetroparts.com\/products\/emerson-deltav-kj3225x1-ba1-rtd-resistance-input-card","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}