{"product_id":"emerson-deltav-kj3243x1-bb2-profibus-dp-card-series-2-plus-m-series","title":"Emerson DeltaV KJ3243X1-BB2 Profibus DP Card Series 2 Plus M-Series","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson KJ3243X1-BB2\u003c\/strong\u003e is a \u003cstrong\u003eSeries 2 Plus Profibus DP Interface Card\u003c\/strong\u003e for the DeltaV™ distributed control system. It provides high-speed, reliable communication between DeltaV controllers and Profibus DP field devices, including remote I\/O stations, variable frequency drives, and smart sensors. The \"Plus\" variant offers enhanced performance compared to the standard KJ3243X1-BA1.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KJ3243X1-BB2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Series 2 Plus Profibus DP Interface Card\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e Profibus DP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 12 VDC at 600 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 4.3 × 12.5 × 18.5 cm (standard S-Series form factor)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.4 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEnvironmental \u0026amp; Hazardous Area Ratings\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 10g, ½ sine wave for 11 ms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 1 mm peak-to-peak (2–13.2 Hz); 0.7g (13.2–150 Hz)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAirborne Contaminants:\u003c\/strong\u003e ISA-S71.04 Class G3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area:\u003c\/strong\u003e II 3G Ex ec IIC Gc, Class I Div. 2 Groups A–D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e FM19ATEX0173U, IECEx FMG 19.0019U, FM21UKEX0017U\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure all field and system power is removed before inserting or removing the card in hazardous areas.\u003c\/li\u003e\n  \u003cli\u003eInstall the card in an 8-wide I\/O carrier slot in the DeltaV S-Series chassis.\u003c\/li\u003e\n  \u003cli\u003eSet the terminal block rotary key to the correct position for Profibus DP compatibility.\u003c\/li\u003e\n  \u003cli\u003eConnect the Profibus DP cable to the terminal block, ensuring proper termination at network ends.\u003c\/li\u003e\n  \u003cli\u003eConfigure the Profibus network in DeltaV Explorer, assigning device addresses and mapping I\/O data.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: What is the difference between KJ3243X1-BB2 and KJ3243X1-BA1?\u003c\/strong\u003e\u003cbr\u003eA: The BB2 is the \"Series 2 Plus\" variant, offering enhanced performance and features compared to the standard BA1 Profibus DP card.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: What baud rates does Profibus DP support?\u003c\/strong\u003e\u003cbr\u003eA: Profibus DP supports baud rates from 9.6 Kbps up to 12 Mbps, auto-negotiated or manually configured.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: How many devices can be connected?\u003c\/strong\u003e\u003cbr\u003eA: A single Profibus DP master can address up to 126 devices, depending on network configuration and data throughput.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: Is redundancy supported?\u003c\/strong\u003e\u003cbr\u003eA: Redundancy depends on system architecture; consult DeltaV documentation for redundant Profibus DP configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eChoose KJ3243X1-BB2 for new installations requiring the latest Series 2 Plus performance and feature set.\u003c\/li\u003e\n  \u003cli\u003eUse KJ3243X1-BA1 only when replacing existing standard Series 2 cards to maintain consistency.\u003c\/li\u003e\n  \u003cli\u003eEnsure Profibus DP cable meets IEC 61158 standards and uses proper shielding\/grounding for reliable communication.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53768203731128,"sku":"KJ3243X1-BB2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/KJ3243X1-BB1EmersonDeltaVProfibusDPInterfaceCard_1.jpg?v=1773986041","url":"https:\/\/www.globalpetroparts.com\/products\/emerson-deltav-kj3243x1-bb2-profibus-dp-card-series-2-plus-m-series","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}