{"product_id":"emerson-deltav-kl3003x1-ba1-digital-input-charm","title":"Emerson DeltaV KL3003X1-BA1 Digital Input CHARM","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL3003X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input CHARM integrates seamlessly within Emerson DeltaV distributed control systems for precise signal acquisition.\u003cbr\u003eThis module processes 24 VDC dry contact signals efficiently while maintaining stable performance in demanding industrial automation environments.\u003cbr\u003eEngineers choose\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL3003X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebecause it simplifies wiring, reduces cabinet space, and improves overall system scalability.\u003c\/p\u003e\n\u003cp\u003eMoreover, Emerson designs this CHARM module to support fast installation and reliable long-term operation across various process industries.\u003cbr\u003eIts compact architecture allows flexible deployment within CHARMs I\/O cards while maintaining consistent signal integrity during operation.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eKL3003X1-BA1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eDeltaV CHARM I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input CHARM (Characterization Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eDeltaV Electronic Marshalling System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDry Contact Digital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eBinary ON\/OFF (open\/closed contact detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Sensing Method\u003c\/td\u003e\n\u003ctd\u003eLow-side sensing for accurate discrete signal detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCHARM Bus Power\u003c\/td\u003e\n\u003ctd\u003e+6.3 VDC at approximately 32 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Power\u003c\/td\u003e\n\u003ctd\u003e+24 VDC at approximately 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Architecture\u003c\/td\u003e\n\u003ctd\u003eDual power domains (bus power + field loop power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eElectrical isolation between field and system interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing Delay\u003c\/td\u003e\n\u003ctd\u003eTypical 2–3 ms response time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eDirect installation on CHARM terminal block with automatic keying\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Interface\u003c\/td\u003e\n\u003ctd\u003ePluggable CHARM baseplate connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eBuilt-in diagnostics for open circuit and signal state monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C (typical industrial standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak (2–13.2 Hz); 0.7 g (13.2–150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10 g, half-sine wave for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC \/ Environment Rating\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04 Class G3 (harsh industrial environments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Certifications\u003c\/td\u003e\n\u003ctd\u003eATEX, IECEx, FM, UKEX compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Level\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade design for noise and surge immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.3–0.4 W per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 50 g to 454 g (depending on configuration and packaging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact CHARM form factor for high-density I\/O deployment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Feature\u003c\/td\u003e\n\u003ctd\u003eAuto-keying prevents incorrect insertion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Devices\u003c\/td\u003e\n\u003ctd\u003ePush buttons, limit switches, relay contacts, dry contact sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp data-start=\"3147\" data-end=\"3310\"\u003e\u003cstrong data-start=\"3147\" data-end=\"3202\"\u003eQ1: What type of signals does KL3003X1-BA1 support?\u003c\/strong\u003e\u003cbr data-start=\"3202\" data-end=\"3205\"\u003eThe \u003cstrong data-start=\"3209\" data-end=\"3225\"\u003eKL3003X1-BA1\u003c\/strong\u003e supports 24 VDC dry contact digital input signals from switches and relay devices.\u003c\/p\u003e\n\u003cp data-start=\"3312\" data-end=\"3513\"\u003e\u003cstrong data-start=\"3312\" data-end=\"3382\"\u003eQ2: Can this module integrate easily into existing DeltaV systems?\u003c\/strong\u003e\u003cbr data-start=\"3382\" data-end=\"3385\"\u003eYes, the \u003cstrong data-start=\"3394\" data-end=\"3410\"\u003eKL3003X1-BA1\u003c\/strong\u003e integrates directly with DeltaV CHARM I\/O cards, which simplifies expansion and configuration tasks.\u003c\/p\u003e\n\u003cp data-start=\"3515\" data-end=\"3718\"\u003e\u003cstrong data-start=\"3515\" data-end=\"3590\"\u003eQ3: Does the module provide protection against electrical interference?\u003c\/strong\u003e\u003cbr data-start=\"3590\" data-end=\"3593\"\u003eYes, the \u003cstrong data-start=\"3602\" data-end=\"3618\"\u003eKL3003X1-BA1\u003c\/strong\u003e includes channel isolation, which improves noise immunity and ensures reliable signal processing.\u003c\/p\u003e\n\u003cp data-start=\"3720\" data-end=\"3869\"\u003e\u003cstrong data-start=\"3720\" data-end=\"3769\"\u003eQ4: What is the delivery and stock situation?\u003c\/strong\u003e\u003cbr data-start=\"3769\" data-end=\"3772\"\u003eThis product is brand new and original, and we keep stock available for fast order fulfillment.\u003c\/p\u003e\n\u003cp data-start=\"3871\" data-end=\"4020\"\u003e\u003cstrong data-start=\"3871\" data-end=\"3913\"\u003eQ5: How fast can shipping be arranged?\u003c\/strong\u003e\u003cbr data-start=\"3913\" data-end=\"3916\"\u003eWe usually ship within 3 days to 2 weeks, depending on order size and logistics arrangements like DHL.\u003c\/p\u003e\n\u003cp data-start=\"4022\" data-end=\"4154\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"4022\" data-end=\"4071\"\u003eQ6: What happens if there is a quality issue?\u003c\/strong\u003e\u003cbr data-start=\"4071\" data-end=\"4074\"\u003eWe support returns within 30 days if any quality problem appears after delivery.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53095452639416,"sku":"KL3003X1-BA1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/EmersonDeltaVKL3003X1-BA1DigitalInputCHARM_3.jpg?v=1774404368","url":"https:\/\/www.globalpetroparts.com\/products\/emerson-deltav-kl3003x1-ba1-digital-input-charm","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}