{"product_id":"emerson-deltav-ve5008-dc-power-supply-module-calculate-shipping-quotation-request","title":"Emerson DeltaV VE5008 DC Power Supply Module Calculate shipping Quotation Request","description":"\u003ch2 data-section-id=\"1n8lizy\" data-start=\"271\" data-end=\"291\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE5008\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDC power supply module provides stable and efficient power for Emerson DeltaV M-Series control systems.\u003cbr\u003eIt converts bulk 24 VDC input into regulated system voltages while ensuring reliable operation across industrial environments.\u003c\/p\u003e\n\u003cp\u003eMoreover,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE5008\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeliminates external bulk 12 VDC supplies by distributing power through the LocalBus architecture.\u003cbr\u003eThis approach simplifies cabinet design while improving wiring efficiency and overall system reliability.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eVE5008\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eDeltaV M-Series Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC ±20% or 12 VDC (-4% to +5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e6.1 A at 24 VDC \/ 14.8 A at 12 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e20 A peak at 24 VDC, 12 A peak at 12 VDC (5 ms duration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e+12 VDC, +5 VDC, +3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current (≤60°C)\u003c\/td\u003e\n\u003ctd\u003e12 VDC: 8.0 A (24 V input) \/ 13 A (12 V input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current (60–70°C)\u003c\/td\u003e\n\u003ctd\u003e12 VDC: 6.0 A (24 V input) \/ 10 A (12 V input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Output Power\u003c\/td\u003e\n\u003ctd\u003e5 VDC at 2.0 A, 3.3 VDC at 2.0 A (10 W combined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003e110% to 120% output protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-up Time\u003c\/td\u003e\n\u003ctd\u003e5 ms within ±5% at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Isolation\u003c\/td\u003e\n\u003ctd\u003eSystem power isolated from field power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e2-wide or 4-wide DeltaV carrier slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003ePassive convection cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended Temperature\u003c\/td\u003e\n\u003ctd\u003e+60°C to +70°C with derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10 g, 11 ms half-sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e1 mm peak-to-peak (5–16 Hz), 0.5 g (16–150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eInternal non-replaceable fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicators\u003c\/td\u003e\n\u003ctd\u003eGreen (power), Red (fault)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Contact\u003c\/td\u003e\n\u003ctd\u003eRelay output, 2 A at 30 VDC \/ 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003e2-wire DC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eATEX Zone 2, FM Class 1 Div 2, IEC standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 130 mm × 45 mm × 250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003csection\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What input voltage does VE5008 support?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE5008\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both 24 VDC and 12 VDC input power for flexible system integration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What output current can this module deliver?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE5008\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers up to 8 A at 12 VDC using a 24 VDC input source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does VE5008 provide electrical isolation?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVE5008\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eisolates system power from field power, which improves safety and noise immunity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the delivery and stock status?\u003c\/strong\u003e\u003cbr\u003eThis product is brand new and original, and we keep stock available for immediate shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How fast can shipping be arranged?\u003c\/strong\u003e\u003cbr\u003eWe usually ship within 3 days to 2 weeks, depending on order size and logistics such as DHL.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: What happens if there is a quality issue?\u003c\/strong\u003e\u003cbr\u003eWe support returns within 30 days if any quality issue appears after delivery.\u003c\/p\u003e\n\u003c\/section\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53095543341240,"sku":"VE5008","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/EmersonDeltaVVE5008DCPowerSupplyModuleCalculateshippingQuotationRequest_3.jpg?v=1774410905","url":"https:\/\/www.globalpetroparts.com\/products\/emerson-deltav-ve5008-dc-power-supply-module-calculate-shipping-quotation-request","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}