{"product_id":"emerson-epro-con021-pr6424-013-140-eddy-current-signal-converter","title":"Emerson Epro CON021+PR6424\/013-140 Eddy Current Signal Converter","description":"\u003ch2 data-end=\"291\" data-start=\"271\" data-section-id=\"1n8lizy\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"256\" data-end=\"788\"\u003eThe \u003cstrong data-start=\"278\" data-end=\"303\"\u003eCON021+PR6424\/013-140\u003c\/strong\u003e from Emerson Epro delivers high-precision signal conversion for industrial eddy current monitoring systems.\u003cbr data-start=\"411\" data-end=\"414\"\u003eMoreover, this model integrates the \u003cstrong data-start=\"450\" data-end=\"460\"\u003eCON021\u003c\/strong\u003e converter with the \u003cstrong data-start=\"480\" data-end=\"498\"\u003ePR6424\/013-140\u003c\/strong\u003e probe for reliable vibration and shaft displacement measurement.\u003cbr data-start=\"563\" data-end=\"566\"\u003eAdditionally, the \u003cstrong data-start=\"584\" data-end=\"609\"\u003eCON021+PR6424\/013-140\u003c\/strong\u003e supports high-speed rotating machinery, turbines, and compressors in harsh industrial environments.\u003cbr data-start=\"709\" data-end=\"712\"\u003eTherefore, engineers rely on this system for consistent and accurate monitoring performance across critical equipment.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCON021+PR6424\/013-140\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEddy Current Signal Converter System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Model\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePR6424\/013-140\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Model\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eNon-contact eddy current sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0 to 4 mm (typical calibrated range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e4 mV\/µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA or dynamic voltage output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eDC to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e≤ ±1% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e≤ 1 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e≤ 0.2% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003eStandard modular cable, 3 m recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Probe)\u003c\/td\u003e\n\u003ctd\u003e−35 °C to +180 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature (Converter)\u003c\/td\u003e\n\u003ctd\u003e−30 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003eM14 × 1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP65 when installed correctly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e−24 VDC via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.5–0.7 kg total system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eConductive metals such as steel or alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eFactory-matched probe and converter system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Compatibility\u003c\/td\u003e\n\u003ctd\u003ePLC, DCS, and Emerson AMS systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Resistance\u003c\/td\u003e\n\u003ctd\u003eHigh immunity to electromagnetic interference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the product new and original?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021+PR6424\/013-140\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis brand new and original from Emerson Epro.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Do you have stock available?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021+PR6424\/013-140\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis in stock for immediate supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How fast can you ship the product?\u003c\/strong\u003e\u003cbr\u003eWe ship within 3 days to 2 weeks depending on order quantity and stock availability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Which logistics services are used?\u003c\/strong\u003e\u003cbr\u003eWe use DHL and other international carriers for fast and secure delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What output signals does this system provide?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021+PR6424\/013-140\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides 4–20 mA and dynamic voltage outputs compatible with industrial monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: What is the typical measurement range?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCON021+PR6424\/013-140\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports 0 to 4 mm depending on calibration and probe setup.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53224519893176,"sku":"CON021+PR6424\/013-140","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/EmersonEproCON021_PR6424013-140EddyCurrentSignalConverter_3.jpg?v=1775180487","url":"https:\/\/www.globalpetroparts.com\/products\/emerson-epro-con021-pr6424-013-140-eddy-current-signal-converter","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}