{"product_id":"emerson-ovation-5x00063g01-hart-analog-output-module","title":"Emerson Ovation 5X00063G01 Hart Analog Output Module","description":"\u003ch3\u003eEmerson Ovation 5X00063G01 – 8-Channel HART Analog Output Module\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson Ovation 5X00063G01\u003c\/strong\u003e is an \u003cstrong\u003e8-channel analog output module\u003c\/strong\u003e with integrated HART communication for the Ovation Distributed Control System. It delivers 4–20 mA control signals to field actuators and supports HART digital overlay for device diagnostics and remote configuration.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 8 isolated analog output channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Range:\u003c\/strong\u003e 4–20 mA, 0–20 mA configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit digital-to-analog conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e 0.1% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Protocol:\u003c\/strong\u003e Full HART digital communication on all channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 1000 V between channels and power supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC, backplane-fed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e −40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e −40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.27 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 120 mm × 80 mm × 20 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e5X00063G01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson Ovation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module with HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA, 0–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Impedance\u003c\/td\u003e\n\u003ctd\u003e500 Ω maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1000 V channel-to-channel, channel-to-ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e100 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eOvation standard I\/O rack, hot-swappable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Device Diagnostics\u003c\/strong\u003e\u003cbr\u003eThe 5X00063G01 supports HART protocol overlay on all 8 channels. This enables digital diagnostics, calibration, and configuration of HART-enabled field devices without additional wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load Per Channel\u003c\/strong\u003e\u003cbr\u003eEach channel drives 500 Ω at 24 VDC. Total loop resistance including cable and device must not exceed 500 Ω.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swap Support\u003c\/strong\u003e\u003cbr\u003eThe module inserts and removes from a powered Ovation I\/O rack without system shutdown. The rack must support hot-swap functionality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Range Selection\u003c\/strong\u003e\u003cbr\u003eThe output range is software-configurable via Ovation configuration tools. Select 4–20 mA or 0–20 mA per channel.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 1:\u003c\/strong\u003e Power down the I\/O rack or confirm hot-swap capability. Wear an anti-static wrist strap.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 2:\u003c\/strong\u003e Align the module with the keyed slot in the Ovation I\/O chassis. Insert firmly until latches engage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 3:\u003c\/strong\u003e Connect field wiring to screw terminals. Connect + (sourcing) to actuator +, − to common.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 4:\u003c\/strong\u003e In Ovation Developer Studio, add 5X00063G01 to the I\/O tree. Assign channel tags and select 4–20 mA or 0–20 mA range per channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 5:\u003c\/strong\u003e Perform loop check. Verify each channel drives expected current into a 250 Ω test load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cp\u003eChoose \u003cstrong\u003e5X00063G01\u003c\/strong\u003e for \u003cstrong\u003e8-channel analog output with HART intelligence\u003c\/strong\u003e for valve positioners, VFDs, and smart actuators. For applications without HART, the 1C31132G01 analog output personality module is the alternative. For 16-channel output density, use 5X00590G01. Confirm backplane revision compatibility with the Ovation controller.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53864813854904,"sku":"5X00063G01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/5X00063G012r180.png?v=1785815133","url":"https:\/\/www.globalpetroparts.com\/products\/emerson-ovation-5x00063g01-hart-analog-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}