{"product_id":"emerson-ovation-5x00119g02-rtd-input-module-8-channels","title":"Emerson Ovation 5X00119G02 RTD Input Module - 8 Channels","description":"\u003ch3\u003eEmerson Ovation 5X00119G02 – 8-Channel RTD Input Module\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson Ovation 5X00119G02\u003c\/strong\u003e is an \u003cstrong\u003e8-channel RTD input module\u003c\/strong\u003e for high-accuracy temperature measurement in the Ovation DCS. It supports platinum and nickel RTD types with 2-wire, 3-wire, and 4-wire configurations.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 8 RTD inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported RTD Types:\u003c\/strong\u003e PT100, PT1000, Ni20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e −200°C to +850°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e 0.1% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit A\/D conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 100 ms per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e High impedance to minimize signal degradation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e −20°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e −40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5%–95% RH non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 180 mm × 50 mm × 120 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.8 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e5X00119G02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e8-Channel RTD Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Types\u003c\/td\u003e\n\u003ctd\u003ePt100, Pt1000, Ni20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp Range\u003c\/td\u003e\n\u003ctd\u003e−200°C to +850°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Config\u003c\/td\u003e\n\u003ctd\u003e2-wire, 3-wire, 4-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp Range\u003c\/td\u003e\n\u003ctd\u003e−20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible RTD Types\u003c\/strong\u003e\u003cbr\u003eThe module supports Pt100, Pt1000, Ni20, and common industrial RTD sensors. Select the sensor curve (IEC 60751 or JIS) in the configuration software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-Wire RTD Support\u003c\/strong\u003e\u003cbr\u003e2-wire, 3-wire, and 4-wire RTD configurations are supported. 4-wire eliminates lead resistance and provides the highest accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifference From 5X00119G03\u003c\/strong\u003e\u003cbr\u003eG03 adds enhanced diagnostics, wider RTD type support, and improved isolation. G02 is the standard 8-channel variant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swap Capability\u003c\/strong\u003e\u003cbr\u003eThe module supports hot-swap replacement when installed in a compatible Ovation rack.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 1:\u003c\/strong\u003e Install the module into the Ovation RTD I\/O slot. Confirm keying matches to prevent mis-insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 2:\u003c\/strong\u003e Wire RTD sensors to the terminal block. For 3-wire, connect two leads to one excitation terminal and the third to the sense terminal. For 4-wire, separate excitation and sense pairs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 3:\u003c\/strong\u003e In Ovation Developer Studio, assign RTD type, wire configuration, and engineering units (°C or °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 4:\u003c\/strong\u003e Enable open-circuit and short-circuit diagnostics to detect sensor failures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep 5:\u003c\/strong\u003e Verify readings against a calibrated temperature bath or ice-point reference (0°C for Pt100 = 100.00 Ω).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cp\u003eSelect \u003cstrong\u003e5X00119G02\u003c\/strong\u003e for \u003cstrong\u003e8-channel temperature monitoring\u003c\/strong\u003e with Pt100 and Ni20 RTDs. For 4-channel applications, 5X00118G02 provides a smaller footprint. For 16-channel density, use 5X00120G02. For long cable runs, 4-wire RTDs eliminate lead resistance errors.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":53864826699960,"sku":"5X00119G02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/5X00119G02.png?v=1785815218","url":"https:\/\/www.globalpetroparts.com\/products\/emerson-ovation-5x00119g02-rtd-input-module-8-channels","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}