{"product_id":"f-3113a-hima-himatrix-digital-output-module","title":"F 3113A | HIMA  HIMatrix Digital Output Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHIMA F 3113A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a high-integrity digital output interface within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHIMatrix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety controller family. It translates safety logic commands into physical signals to drive field actuators, valves, and contactors. This module provides the essential final-element control required to maintain\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety loops in hazardous process environments. By integrating internal diagnostic testing, the F 3113A ensures that safety functions execute exactly when demanded.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original Factory Sealed.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThis compact module maximizes rack density without compromising electrical isolation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHIMA Paul Hildebrandt GmbH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (DO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 cm x 6 cm x 10.4 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.08 KG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 3 Capable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHIMatrix Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Slim Form Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 2 cm width allows for high-density I\/O configurations. Engineers can pack more control loops into existing cabinet spaces, reducing the total footprint of the Safety Instrumented System (SIS).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Internal Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module continuously monitors its internal circuitry and output states. It detects short circuits or cross-talk instantaneously, triggering a safe state before a field failure can impact the process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite its compact 0.08 KG build, the F 3113A features low-power dissipation architecture. This minimizes heat buildup within the subrack, protecting nearby CPU and communication modules from thermal-induced drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F 3113A utilizes standard HIMatrix bus connectors. This \"plug-and-play\" compatibility allows for rapid hot-swapping or system expansion during planned maintenance windows, minimizing process downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the F 3113A require external fuses for each channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F 3113A includes internal electronic protection; however, we recommend following the HIMA safety manual for specific field-side fusing to protect external cabling based on your specific load requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the F 3113A in high-vibration offshore environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. HIMA designs the HIMatrix series for rugged industrial use. The F 3113A meets the vibration and shock resistance standards required for oil and gas platforms and maritime applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle inductive loads like large solenoid valves?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F 3113A incorporates suppression circuitry to manage back-EMF. For extremely large inductive loads, always verify the peak current ratings against the technical data sheet to ensure long-term relay life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a direct replacement for non-'A' version modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 'A' suffix typically denotes a hardware revision or improved component sourcing. In most HIMatrix configurations, it maintains backward compatibility, but you should verify your SILworX project configuration before commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":53084160229560,"sku":"F3113A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/F3113A.png?v=1774316780","url":"https:\/\/www.globalpetroparts.com\/products\/f-3113a-hima-himatrix-digital-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}