{"product_id":"f3cx04-0n-yokogawa-temperature-monitoring-module","title":"F3CX04-0N | Yokogawa - Temperature Monitoring Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3CX04-0N\u003c\/strong\u003e is a \u003cstrong\u003e4-channel universal temperature monitoring module\u003c\/strong\u003e for the FA-M3 series. It accepts \u003cstrong\u003eThermocouple, RTD (Resistance Temperature Detector), and DC voltage\/mV\u003c\/strong\u003e inputs, providing flexible temperature measurement across critical industrial processes. With a \u003cstrong\u003e200 ms sampling period\u003c\/strong\u003e for all four channels and \u003cstrong\u003e0.1% conversion accuracy\u003c\/strong\u003e, it delivers precise, timely temperature feedback for process control applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 4 independent universal inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Sensors:\u003c\/strong\u003e Thermocouple, RTD, DC Voltage\/mV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Sampling Period:\u003c\/strong\u003e 200 ms for all 4 channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConversion Accuracy:\u003c\/strong\u003e 0.1% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.1°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Photocouplers and transformers, 1500V AC withstand voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Types:\u003c\/strong\u003e Upper\/lower limit alarms (4 points per channel, 4 alarm types selectable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm ON-Delay Function:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 28.9(W) × 100(H) × 104.2(D) mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 160 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e Powered via FA-M3 backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility \u0026amp; Applications\u003c\/h3\u003e\n\u003cp\u003eInstalls in any standard I\/O slot of FA-M3 base modules. Perfect for \u003cstrong\u003eheat treatment ovens, chemical reactors, HVAC systems, food processing, and pharmaceutical sterilization\u003c\/strong\u003e where multi-channel temperature monitoring with alarm functionality is essential.\u003c\/p\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can each channel be configured for different sensor types?\u003c\/strong\u003e A: Yes, each of the 4 channels is independently configurable for TC, RTD, or DC voltage inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the isolation rating?\u003c\/strong\u003e A: 1500V AC for 1 minute between input terminals and internal circuit, using photocoupler and transformer isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it support alarm delay?\u003c\/strong\u003e A: Yes, the ON-delay function prevents nuisance alarms from brief temperature spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is external power required?\u003c\/strong\u003e A: No, the module is powered directly from the FA-M3 backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower off the FA-M3 system.\u003c\/li\u003e\n\u003cli\u003eInsert F3CX04-0N into any available I\/O slot on the base module.\u003c\/li\u003e\n\u003cli\u003eConnect temperature sensors to the detachable 18-point terminal block (M3.5 screws).\u003c\/li\u003e\n\u003cli\u003eConfigure input types and alarm setpoints via WideField3 programming software.\u003c\/li\u003e\n\u003cli\u003eRestore power and verify input LED indicators match sensor status.\u003c\/li\u003e\n\u003cli\u003eCalibrate if necessary using known temperature references.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse F3CX04-0N when you need \u003cstrong\u003euniversal temperature inputs\u003c\/strong\u003e (TC + RTD + DCV) in a single module.\u003c\/li\u003e\n\u003cli\u003eFor higher channel counts, consider multiple F3CX04-0N modules or F3CX08 variants if available.\u003c\/li\u003e\n\u003cli\u003eEnsure sensor wiring uses shielded cables to maximize noise immunity in high-EMI environments.\u003c\/li\u003e\n\u003cli\u003ePair with F3CU04-1S PID module for closed-loop temperature control applications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53930235494584,"sku":"F3CX04-0N","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/F3CX04-0N.png?v=1786952343","url":"https:\/\/www.globalpetroparts.com\/products\/f3cx04-0n-yokogawa-temperature-monitoring-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}