{"product_id":"f3le12-0t-yokogawa-ethernet-interface-module","title":"F3LE12-0T | Yokogawa - Ethernet Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3LE12-0T\u003c\/strong\u003e is an \u003cstrong\u003eEthernet interface module\u003c\/strong\u003e for FA-M3 Range-free Multi-Controllers, enabling high-speed data exchange between the FA-M3 controller and external devices including PCs, workstations, and other controllers. Supporting \u003cstrong\u003eTCP\/IP and UDP\/IP\u003c\/strong\u003e protocols with \u003cstrong\u003e10BASE-T \/ 100BASE-TX\u003c\/strong\u003e auto-negotiation, it provides reliable industrial Ethernet connectivity in a compact single-slot design.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Standard:\u003c\/strong\u003e IEEE 802.3 compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Speeds:\u003c\/strong\u003e 10BASE-T \/ 100BASE-TX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e TCP\/IP, UDP\/IP, ICMP, ARP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e RJ-45 Ethernet port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Mode:\u003c\/strong\u003e Full-duplex \/ Half-duplex auto-negotiation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Cable Length:\u003c\/strong\u003e 100 meters (Cat 5 or higher)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 28.9 mm (W) × 100 mm (H) × 83.2 mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 100 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 330 mA max at 5V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -25°C to +75°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility \u0026amp; Applications\u003c\/h3\u003e\n\u003cp\u003eCompatible with FA-M3 CPU modules F3SP66, F3SP67, F3SP71, F3SP76 (with network functions) and all standard FA-M3 CPUs via hub connection. Ideal for \u003cstrong\u003eSCADA integration, remote monitoring, MES\/ERP connectivity, and distributed control systems\u003c\/strong\u003e requiring seamless Ethernet communication.\u003c\/p\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum number of concurrent connections?\u003c\/strong\u003e A: The module supports communication with up to 30 subsystem stations per ALE111 communication link.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use a crossover cable for direct PC connection?\u003c\/strong\u003e A: Yes, for 10BASE-T connections, a crossover cable can be used for peer-to-peer connection without a hub.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is Modbus\/TCP supported?\u003c\/strong\u003e A: Yes, the module supports Modbus\/TCP slave functionality for integration with third-party systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does it require an external power supply?\u003c\/strong\u003e A: No, power is supplied directly via the FA-M3 backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower off the FA-M3 system.\u003c\/li\u003e\n\u003cli\u003eInsert F3LE12-0T into any available I\/O slot.\u003c\/li\u003e\n\u003cli\u003eConnect a standard Cat 5\/6 Ethernet cable to the RJ-45 port.\u003c\/li\u003e\n\u003cli\u003eConfigure IP address, subnet mask, and gateway via WideField3 or ladder logic.\u003c\/li\u003e\n\u003cli\u003eRestore power and verify link\/activity LEDs on the module.\u003c\/li\u003e\n\u003cli\u003eTest connectivity by pinging the module from a networked PC.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChoose F3LE12-0T for \u003cstrong\u003e100 Mbps Ethernet\u003c\/strong\u003e connectivity in FA-M3 systems.\u003c\/li\u003e\n\u003cli\u003eFor older systems requiring 10 Mbps only, F3LE01-5T or F3LE11-0T may be sufficient.\u003c\/li\u003e\n\u003cli\u003eEnsure your network infrastructure supports industrial Ethernet with proper shielding and grounding.\u003c\/li\u003e\n\u003cli\u003eUse F3LE12-0T with F3SP71-4S or F3SP76 CPUs for optimal network performance and large data throughput.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53930237231288,"sku":"F3LE12-0T","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/F3LE12-0T.png?v=1786952335","url":"https:\/\/www.globalpetroparts.com\/products\/f3le12-0t-yokogawa-ethernet-interface-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}