{"product_id":"fail-safe-digital-output-module-10201-2-1-honeywell","title":"Fail-Safe Digital Output Module 10201-2-1 Honeywell","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10201\/2\/1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10201\/2\/1\u003c\/strong\u003e) is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-integrity Fail-Safe Digital Output (DO) Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor Honeywell\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFail Safe Control (FSC) systems\u003c\/strong\u003e. It features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eeight independent 24 V DC solid-state outputs\u003c\/strong\u003e, each capable of sourcing up to 550 mA. The module is purpose-built to drive\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecritical loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as solenoids, relays, and indicator lamps, providing safe de-energization for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eemergency shutdown (ESD) and safety-critical loops\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSafety is embedded through\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtinuous self-testing\u003c\/strong\u003e, verifying the de-energization of individual channels, crosstalk detection, and suppression diode integrity. Integrated protection against inductive loads and full compliance with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTUV and UL standards\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emake it suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL-rated safety instrumented systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein oil, gas, and chemical processing environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10201\/2\/1 (10201-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Independent 24 V DC Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e550 mA per channel (short-circuit proof)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 13 W (resistive or inductive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Lamp Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 mA (2.9 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.0 V DC at 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-State Leakage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Testing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDe-energization capability, crosstalk detection, diode integrity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC (25 mA), 24 V DC Internal (25 mA), 24 V DC External (70 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpace Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 HP (TE), 3 U (HE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 cm × 20 cm × 15 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDriving\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESD solenoid valves\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein gas processing and chemical plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eActivating\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecritical safety sirens and status lamps\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein industrial facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfacing with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efail-safe interposing relays\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor high-power equipment isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImplementing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL-3 rated safety loops\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the Honeywell FSC architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 10201\/2\/1 require external diodes for inductive loads?\u003c\/strong\u003e\u003cbr\u003eNo. Each output channel has an integrated suppression diode for back-EMF protection. These diodes are continuously monitored as part of the module’s fail-safe testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a short circuit occurs on an output?\u003c\/strong\u003e\u003cbr\u003eThe module is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshort-circuit proof\u003c\/strong\u003e. Internal protection prevents damage, and the fault is reported to the FSC system for operator intervention.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52521102180536,"sku":"10201\/2\/1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/1020121_16b3fc13-6430-4ec4-880b-a0788b50b514.jpg?v=1770017080","url":"https:\/\/www.globalpetroparts.com\/products\/fail-safe-digital-output-module-10201-2-1-honeywell","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}