{"product_id":"fastbus-slave-module-bachmann-fs222-n","title":"FASTBUS Slave Module Bachmann FS222\/N","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFS222\/N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-reliability fiber optic interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the Bachmann M1 system. Operating as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFASTBUS slave\u003c\/strong\u003e, it extends the system bus over long distances while providing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einterference-free communication\u003c\/strong\u003e. The module integrates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e17 W power supply\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto energize remote I\/O racks, and supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant dual fiber paths\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor automatic failover, ensuring robust and reliable distributed control.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Interface\u003c\/td\u003e\n\u003ctd\u003eDual multimode FO ports (50\/62.5 µm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Distance\u003c\/td\u003e\n\u003ctd\u003eUp to 2000 m per segment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Power Supply\u003c\/td\u003e\n\u003ctd\u003e17 W total output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rails\u003c\/td\u003e\n\u003ctd\u003e+5 V 2 A; +15 V 250 mA; −15 V 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (18–34 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw\u003c\/td\u003e\n\u003ctd\u003eMax 0.7 A at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eHarting PushPull or LC patch cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V (system bus ↔ field side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003eStandard −30 °C to +60 °C; cold-climate −40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eRUN\/ERR and Fiber Type indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWind farms and renewable energy plants\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHydroelectric facilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaritime vessels and engine room sub-stations\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eremote backplane powering\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elong-distance fiber communication\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require a separate power supply for the remote rack?\u003c\/strong\u003e\u003cbr\u003eA: No, the built-in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e17 W supply\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epowers the remote backplane and a limited number of I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the redundancy feature work?\u003c\/strong\u003e\u003cbr\u003eA: Dual fiber lines allow\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eautomatic failover\u003c\/strong\u003e; if the primary link fails or degrades, the system switches to the secondary line.\u003c\/p\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":52528873111736,"sku":"FS222\/N","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/FS222N.jpg?v=1770189911","url":"https:\/\/www.globalpetroparts.com\/products\/fastbus-slave-module-bachmann-fs222-n","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}