{"product_id":"fc-teld-0001-honeywell-uio-earth-leakage-detector","title":"FC-TELD-0001 | Honeywell | UIO Earth Leakage Detector","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-TELD-0001\u003c\/strong\u003e is a \u003cstrong\u003eUIO Earth Leakage Detector\u003c\/strong\u003e designed for Honeywell Safety Manager systems. Operating on \u003cstrong\u003e24 VDC\u003c\/strong\u003e, this module detects \u003cstrong\u003eresidual current (earth leakage)\u003c\/strong\u003e in electrical systems, providing critical protection against electrical shock hazards and potential fire risks. As a \u003cstrong\u003eUniversal Input\/Output (UIO)\u003c\/strong\u003e device, it integrates seamlessly with Safety Manager I\/O architectures to monitor electrical safety in industrial installations, switchgear, and power distribution systems.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection:\u003c\/strong\u003e Monitors residual current to prevent electrical shock and fire hazards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 VDC Operation:\u003c\/strong\u003e Standard industrial voltage compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUIO Interface:\u003c\/strong\u003e Universal Input\/Output compatibility with Safety Manager systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Response Time:\u003c\/strong\u003e Rapid detection of leakage currents for immediate safety response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact \u0026amp; Rugged Design:\u003c\/strong\u003e Suitable for installation in tight spaces and harsh environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Temperature Range:\u003c\/strong\u003e Reliable operation across industrial temperature extremes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Mounting Options:\u003c\/strong\u003e Flexible installation for diverse system requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e FC-TELD-0001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e UIO Earth Leakage Detector \/ Earth Leakage Sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection Principle:\u003c\/strong\u003e Residual current (earth leakage) detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e Universal Input\/Output (UIO), compatible with Safety Manager control systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Fast detection for immediate safety response\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e Compact and rugged industrial enclosure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Multiple mounting options (DIN rail or panel mount, verify variant)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.8 kg (800 g)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Suitability:\u003c\/strong\u003e Built for harsh industrial conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Wide industrial range (verify specific rating in system documentation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, UL, CSA (verify specific certifications for application)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install FC-TELD-0001 in electrical panel or switchgear using appropriate mounting hardware\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect 24 VDC supply to power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Transformer:\u003c\/strong\u003e Install residual current transformer (CT) on monitored power circuit:\n\u003cul\u003e\n\u003cli\u003ePass all live conductors (phases + neutral) through the CT window\u003c\/li\u003e\n\u003cli\u003eEnsure proper CT ratio and sensitivity for application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUIO Connection:\u003c\/strong\u003e Connect UIO signal to Safety Manager input module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThreshold Setting:\u003c\/strong\u003e Configure leakage current alarm threshold via Safety Manager engineering software or local adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Perform injection test to verify proper detection and alarm response\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is earth leakage detection and why is it important?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; Earth leakage detection monitors the difference between current flowing to a load and returning from it. Any imbalance indicates current leaking to earth, which can cause electric shock, equipment damage, or fire. The FC-TELD-0001 provides early warning of these hazardous conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What leakage current threshold should I set?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; Threshold depends on application and local electrical codes. Typical settings: \u003cstrong\u003e30 mA\u003c\/strong\u003e for personnel protection (residual current devices), \u003cstrong\u003e100-300 mA\u003c\/strong\u003e for fire protection, \u003cstrong\u003e10-30 mA\u003c\/strong\u003e for medical\/sensitive equipment. Consult local electrical regulations and system safety requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module include the current transformer?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; The FC-TELD-0001 is the detector module. Current transformers (CTs) are typically ordered separately based on the monitored circuit current rating and conductor size. Verify system documentation for compatible CT models.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this be used in Safety Manager SIL-rated loops?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; The FC-TELD-0001 provides earth leakage monitoring as a safety function. For SIL-rated applications, verify the complete safety loop calculation including this detector, the UIO input module, and the Safety Manager controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between earth leakage detection and ground fault detection?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; Earth leakage detection monitors small residual currents (mA range) for personnel and fire protection. Ground fault detection typically monitors larger fault currents (A range) for equipment protection. The FC-TELD-0001 is designed for sensitive residual current monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT Selection:\u003c\/strong\u003e Order compatible residual current transformer based on monitored circuit current rating and physical conductor size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThreshold Planning:\u003c\/strong\u003e Define alarm and trip thresholds based on:\n\u003cul\u003e\n\u003cli\u003ePersonnel safety requirements (typically ≤ 30 mA)\u003c\/li\u003e\n\u003cli\u003eFire protection requirements (typically 100-300 mA)\u003c\/li\u003e\n\u003cli\u003eEquipment protection requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Verify UIO input module compatibility in Safety Manager chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e For critical applications, consider dual earth leakage detectors with redundant monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e Ensure periodic testing capability (test button or injection test equipment) for maintenance verification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e Verify operating temperature and enclosure rating match installation environment\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53811895926968,"sku":"FC-TELD-0001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/FC-TELD-0001r180.png?v=1785134491","url":"https:\/\/www.globalpetroparts.com\/products\/fc-teld-0001-honeywell-uio-earth-leakage-detector","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}