{"product_id":"fc-tsfire-1624-honeywell-safe-fire-detector-input-field-termination-assembly","title":"FC-TSFIRE-1624 | Honeywell | Safe Fire Detector Input Field Termination Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-TSFIRE-1624\u003c\/strong\u003e is a \u003cstrong\u003eSafe Fire Detector Input Field Termination Assembly (FTA)\u003c\/strong\u003e providing \u003cstrong\u003e16 channels\u003c\/strong\u003e for fire and gas detection devices in Honeywell Safety Manager systems. This FTA provides the critical interface between fire alarm field devices and the safety controller, with specialized line monitoring and fault detection for life safety applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Fire Detector Input Channels:\u003c\/strong\u003e Dedicated for fire and gas detection loops\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecialized Line Monitoring:\u003c\/strong\u003e Enhanced detection of wiring faults in detector circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEOL Resistor Compatible:\u003c\/strong\u003e Supports standard fire alarm end-of-line resistor configurations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Interconnection:\u003c\/strong\u003e SIC cable interface to SFIRE-1624 I\/O modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire \u0026amp; Gas Application Ready:\u003c\/strong\u003e Designed for NFPA and EN 54 compliant systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Universal snap-in for TS32\/TS35 rails\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e FC-TSFIRE-1624\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Safe Fire Detector Input FTA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Fire and gas detector input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e Conventional fire detectors, gas detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Monitoring:\u003c\/strong\u003e Open, short, ground fault detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail:\u003c\/strong\u003e TS32 \/ TS35 × 7.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Size:\u003c\/strong\u003e Max 2.5 mm² (AWG 14)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, TÜV, UL, CSA, FM\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mount:\u003c\/strong\u003e Snap FTA onto TS32\/TS35 rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetector Connection:\u003c\/strong\u003e Wire fire\/gas detectors per loop diagram\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEOL Resistor:\u003c\/strong\u003e Install end-of-line resistors at last detector in each loop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Test:\u003c\/strong\u003e Verify loop integrity using Safety Manager diagnostic tools\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIC Connection:\u003c\/strong\u003e Connect to SFIRE-1624 module via SIC cable\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between FC-TSFIRE-1624 and FS-TSFIRE-1624?\u003c\/strong\u003e\u003cbr\u003eA: They are functionally identical. \"FC-\" and \"FS-\" prefixes denote manufacturing variants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many detectors can be connected per channel?\u003c\/strong\u003e\u003cbr\u003eA: This depends on the detector type and loop current. Refer to detector manufacturer specifications and Safety Manager documentation for maximum loop capacity.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse for fire and gas detection applications in Safety Manager systems\u003c\/li\u003e\n\u003cli\u003eVerify compatibility with specific detector models and EOL configurations\u003c\/li\u003e\n\u003cli\u003eEnsure compliance with local fire safety regulations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53811833176248,"sku":"FC-TSFIRE-1624","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/FC-TSFIRE-1624r180.png?v=1785134498","url":"https:\/\/www.globalpetroparts.com\/products\/fc-tsfire-1624-honeywell-safe-fire-detector-input-field-termination-assembly","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}