{"product_id":"ge-ds200slccg1acc-mark-v-lan-communications-board","title":"GE DS200SLCCG1ACC Mark V LAN Communications Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE DS200SLCCG1ACC (DS200SLCCG1A)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the primary LAN Communications and Drive Control hub for the GE Mark V and Innovation Series drive systems. This SLCC board manages high-speed data exchange via ARCNET and DLAN protocols, serving as the essential link between the drive control processors and the operator interface. We provide this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control architecture utilizes factory-certified hardware for high-bandwidth, deterministic communication. By offloading network management from the core drive logic, the DS200SLCCG1ACC maintains system responsiveness even during heavy data bursts.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDS200SLCCG1ACC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark V \/ Innovation Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLAN Communications Card (SLCC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMicroprocessors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-processor architecture (including 80C186)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eARCNET, DLAN (Drive LAN), RS-232\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1-line, 14-segment Alphanumeric LED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-density ribbon cable connectors (J-ports)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRevision Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG1ACC (Optimized Hardware Stability)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe DS200SLCCG1ACC delivers specialized technical solutions for complex network environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork\/Control Separation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board utilizes a dedicated 80C186 microprocessor to handle all ARCNET and DLAN traffic. This physical separation ensures that communication overhead never interrupts the millisecond-precision timing required for motor speed and torque control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRevision \"G1ACC\" Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis advanced hardware revision features improved decoupling capacitors and optimized trace routing. These enhancements provide superior resistance to electromagnetic interference (EMI), which is critical in cabinets housing high-power switching bridges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Hardware Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn integrated 14-segment LED display provides immediate visual feedback. Engineers can identify initialization errors, LAN timeouts, or hardware parity faults directly from the board face without attaching an external diagnostic computer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy System Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe SLCC design supports seamless integration with older Mark V racks. It acts as a direct replacement for previous G1A series boards, allowing plants to modernize their communication stability without re-engineering the entire backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; System Configuration Protocols\u003c\/h3\u003e\n\u003cp\u003eTo maintain the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewarranty and ensure proper network synchronization, adhere to these engineering standards:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEPROM Migration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe SLCC board requires site-specific configuration software stored in socketed EPROM chips. You must carefully move these chips from your original board to the new DS200SLCCG1ACC. Verify the notch orientation on each chip to prevent logic failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJumper Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNumerous hardware jumpers define the board's LAN ID and signal levels. Match the jumper positions on the new board exactly to the configuration of the unit being replaced to avoid network collisions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eESD Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe communication processors are highly susceptible to static discharge. Utilize a grounded wrist strap and anti-static mat during the entire installation process to prevent \"latent\" damage that could cause intermittent network drops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DS200SLCCG1ACC replace a DS200SLCCG1A or G1ABC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \"G1ACC\" is the most current stable successor in the series. It provides full backward compatibility for all G1 variants while offering better component tolerance and longevity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this board ship with pre-programmed drive logic?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The hardware is brand new and blank. The functional intelligence resides in the socketed EPROMs. You must transfer your existing site-specific chips to the new board for it to communicate with your specific turbine or drive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the signs of a failing SLCC board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCommon indicators include \"Communication Timeout\" alarms at the HMI, the LED display failing to complete its \"ready\" sequence, or intermittent data loss on the ARCNET link that triggers system-wide protective trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53452629508280,"sku":"DS200SLCCG1ACC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/DS200SLCCG1ACC_3_1.jpg?v=1778466510","url":"https:\/\/www.globalpetroparts.com\/products\/ge-ds200slccg1acc-mark-v-lan-communications-board","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}