{"product_id":"ge-ds200slccg3a-mark-v-lan-communications-card","title":"GE | DS200SLCCG3A Mark V LAN Communications Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE DS200SLCCG3A (DS200SLCCG3A)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the primary LAN Communications Card for the GE Mark V Speedtronic turbine control system and associated drive lineups. This board manages the high-speed data exchange between the drive control processors and the broader ARCNET communication network. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal equipment. The DS200SLCCG3A acts as the localized intelligence for the Staged LAN (Local Area Network), allowing the drive to share real-time operational data, alarms, and status updates with the operator interface and other control cores. By offloading communication tasks from the main drive processor, it ensures deterministic control performance for heavy-duty industrial motors and turbine auxiliaries.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe DS200SLCCG3A utilizes a dedicated microprocessor architecture to maintain high-throughput network connectivity in harsh electrical environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDS200SLCCG3A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark V Speedtronic \/ DC2000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eARCNET (802.4)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80196 Microcontroller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSocketed EPROM for LAN Firmware\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232 Configuration Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKey Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatus LEDs for LAN Link and Processor Health\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe DS200SLCCG3A resolves critical data bottleneck and interference issues in large-scale industrial networks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDedicated Network Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing an onboard 80196 microcontroller, the DS200SLCCG3A handles all packet management and token passing independently. This ensures that network traffic surges do not interfere with the motor's high-speed torque or speed regulation loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptically Isolated ARCNET Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board features built-in optical isolation for the network interface. This design prevents ground loops and protects the internal drive logic from high-voltage transients that can travel through long communication cable runs in power plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Hardware Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA set of onboard diagnostic LEDs provides instant visual feedback on network activity and processor readiness. This allows technicians to distinguish between a physical network break and a board-level failure without connecting external diagnostic software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Firmware Updates:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe use of socketed EPROM chips enables engineers to update the LAN communication protocols or baud rates to match site-specific requirements. This modularity ensures the DS200SLCCG3A remains compatible with both legacy and updated Mark V HMI systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DS200SLCCG3A replace a G1A or G2A revision?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe G3A is the advanced revision of the SLCC series. While it generally offers backward compatibility, you must verify that the LAN firmware version on the EPROM matches your drive's software level. We recommend transferring the original EPROMs to the new board if you are matching a specific legacy configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the LAN address for this board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou set the unique LAN ID or \"Station Address\" using the onboard DIP switches. Ensure the address matches the configuration defined in your system's site-specific communication map to avoid network collisions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the RS-232 port on the board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe serial port facilitates local troubleshooting and drive configuration. It allows a technician to connect a PC directly to the communication card to monitor the internal ARCNET traffic and verify the signal integrity of the LAN link.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the signs of a failing communication card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFrequent \"LAN Link Failure\" alarms or intermittent data dropouts on the HMI typically indicate a failing DS200SLCCG3A. If the \"Status\" LED remains off or blinks in a fault pattern, the onboard microcontroller may have encountered a hardware error.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53463678386360,"sku":"DS200SLCCG3A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/DS200SLCCG3A_1_1.jpg?v=1778744092","url":"https:\/\/www.globalpetroparts.com\/products\/ge-ds200slccg3a-mark-v-lan-communications-card","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}