{"product_id":"ge-ds200slccg3afg-mark-v-lan-communications-board","title":"GE DS200SLCCG3AFG Mark V LAN Communications Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE DS200SLCCG3AFG (DS200SLCCG3A)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the primary LAN Communications and Drive Control processor for the GE Mark V and Innovation Series systems. This SLCC board manages high-speed data exchange via ARCNET and DLAN protocols, coordinating information flow between the drive control processors and the operator interface (HMI). We provide this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control architecture utilizes factory-certified hardware for high-bandwidth, deterministic communication. By offloading complex network management from the core drive logic, the DS200SLCCG3AFG maintains optimal system responsiveness during high-traffic operational states.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDS200SLCCG3AFG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark V \/ Innovation Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLAN Communications Card (SLCC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMicroprocessor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-performance 80C186 controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eARCNET, DLAN (Drive LAN), RS-232, RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlphanumeric 14-segment LED status display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRevision Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3AFG (Enhanced Hardware Revision)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe DS200SLCCG3AFG delivers specialized technical solutions for complex industrial network environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAsynchronous Network Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board utilizes a dedicated 80C186 microprocessor to manage ARCNET and DLAN traffic. This architecture ensures that communication overhead never interrupts the millisecond-precision timing required for motor speed and torque control loops, preventing \"jitter\" in the control response.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRevision \"G3AFG\" Robustness:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"G3\" designation indicates a later generation hardware design with improved signal integrity. This revision features hardened decoupling capacitors and optimized PCB trace routing to neutralize the electromagnetic interference (EMI) found in high-power drive cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Real-Time Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe on-board 14-segment LED display provides immediate visual feedback of the board's health. Engineers can identify initialization errors, LAN ID conflicts, or hardware parity faults directly from the board face, significantly reducing the Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Protocol Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board supports both ARCNET for high-speed peer-to-peer data sharing and DLAN for drive-specific control networking, allowing for a consolidated communication footprint within the Mark V rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; System Configuration Protocols\u003c\/h3\u003e\n\u003cp\u003eTo maintain the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewarranty and ensure proper network synchronization, adhere to these engineering standards:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEPROM\/EEPROM Migration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe SLCC board requires site-specific configuration software stored in socketed chips. You must carefully transfer these chips from your original board to the new DS200SLCCG3AFG. Observe the notch orientation on each chip to prevent logical failure or hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJumper Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNumerous hardware jumpers define the board's LAN ID, signal levels, and terminal resistor settings. Match the jumper positions on the new board exactly to the configuration of the unit being replaced to avoid network collisions or signal reflections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eESD Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe communication processors on the SLCC are highly susceptible to static discharge. Utilize a grounded wrist strap and anti-static mat throughout the installation process to prevent \"latent\" damage that could cause intermittent network drops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DS200SLCCG3AFG replace an older DS200SLCCG1A or G2A?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \"G3\" series serves as the advanced successor to the G1 and G2 variants. It maintains the identical mechanical footprint and electrical headers while offering modernized components for better thermal stability and noise immunity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this board ship with my turbine's specific software?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware is brand new and \"blank.\" The functional logic resides in the socketed EPROMs. You must transfer your existing site-specific chips to this new board for it to communicate with your specific turbine or drive system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary indicators of a failing SLCC board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTypical signs include \"Communication Timeout\" alarms at the HMI, the LED display failing to complete its \"Ready\" sequence, or persistent \"Node Offline\" status in the ARCNET diagnostic utility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53452630098104,"sku":"DS200SLCCG3AFG","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/DS200SLCCG3AFG_3_1.jpg?v=1778466636","url":"https:\/\/www.globalpetroparts.com\/products\/ge-ds200slccg3afg-mark-v-lan-communications-board","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}