{"product_id":"ge-ds200tctlg1abb-mark-v-trip-terminal-board","title":"GE | DS200TCTLG1ABB | Mark V Trip Terminal Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCTLG1ABB (DS200TCTLG1ABB) functions as the primary Trip Terminal Board (TCTL) within the GE Speedtronic Mark V control system. This critical safety module serves as the final interface between the control processors and the turbine's emergency trip solenoids. It facilitates the voting logic between the , , and  cores, ensuring that shutdown commands execute with absolute reliability. By managing the electrical paths to the trip quench and fuel isolation valves, the TCTL board acts as the fundamental safeguard for turbine overspeed and mechanical protection. This unit arrives as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and original\u003c\/strong\u003e, providing the pristine relay contacts and circuit integrity required for mission-critical safety applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCTLG1ABB architecture prioritizes fail-safe operation and high-speed signal routing.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDS200TCTLG1ABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark V Speedtronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBoard Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Terminal Board (TCTL)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelay Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated high-integrity trip relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple 50-pin ribbon cable headers (to TCEA\/TCQA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 VDC nominal for trip solenoid loops\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.0 cm x 15.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware-Based Voting Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board physically implements the 2-out-of-3 (2oo3) voting logic for trip signals. This hardware-level redundancy prevents a single processor failure from causing a nuisance trip while ensuring the turbine shuts down safely when a true trip condition exists.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Solenoid Driving:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineers designed the TCTL board with heavy-duty traces and robust relay contacts capable of handling the high inrush currents typical of large DC-powered trip solenoids found on gas and steam turbines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Suppression Circuits:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery trip output includes dedicated suppression components that clamp inductive flyback voltage. This protects both the board's internal relays and the upstream I\/O processors from electrical transients during solenoid de-energization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePassive Protection Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe TCTL operates as a largely passive termination point for safety signals, minimizing the internal logic complexity to increase the Mean Time Between Failures (MTBF) for the entire protection string.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Field Guidelines\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Power Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure both primary and secondary 125 VDC trip power sources are stable before connecting field solenoids. The TCTL board monitors these rails, and voltage dips can trigger diagnostic alarms in the Mark V interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRibbon Cable Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe TCTL board interfaces with the TCEA and TCQA boards via multiple ribbon cables. Ensure each cable seats fully and that the locking ears click into place; loose connections in the trip string will cause \"Trip Hardware Failure\" alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen terminating field wiring to the trip solenoids, use the specified torque for the terminal screws. Loose connections in the trip circuit pose a significant risk of intermittent \"Circuit Open\" faults which could inhibit a safety shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the G1A and G1ABB versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \"G1\" signifies the core group configuration. The \"ABB\" suffix denotes a later hardware revision that incorporates improved relay specifications and updated circuit board artwork. It serves as a direct, backward-compatible replacement for earlier TCTL G1-series boards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this board handle overspeed protection directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The TCTL board acts as the execution point. It receives overspeed trip commands from the TCEA (Emergency Trip) boards and physically opens the circuit to the fuel solenoids. It does not calculate the speed itself but executes the final shutdown command.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I test the trip relays without shutting down the turbine?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The TCTL board supports online testing features through the Mark V's diagnostic software. However, technicians must strictly follow the site-specific \"Trip Test\" procedure to ensure the remaining redundant paths remain closed during the test.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53455788146872,"sku":"DS200TCTLG1ABB","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/DS200TCTLG1ABB_1.jpg?v=1778569350","url":"https:\/\/www.globalpetroparts.com\/products\/ge-ds200tctlg1abb-mark-v-trip-terminal-board","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}