{"product_id":"ge-fanuc-analog-input-module-ic694alg223","title":"GE Fanuc Analog Input Module IC694ALG223","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IC694ALG223\u003c\/strong\u003e is a \u003cstrong\u003e16-Channel Analog Current Input Module\u003c\/strong\u003e for the Emerson PACSystems RX3i programmable automation controller platform. It provides \u003cstrong\u003esingle-ended current inputs\u003c\/strong\u003e configurable for \u003cstrong\u003e4-20 mA, 0-20 mA, or 4-20 mA Enhanced\u003c\/strong\u003e ranges, with alarm limits and open-wire fault detection capabilities.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e IC694ALG223\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PACSystems RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Current Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e \u003cstrong\u003e16 single-ended inputs\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Ranges (Software Configurable):\u003c\/strong\u003e\n  \u003cul\u003e\n    \u003cli\u003e\u003cstrong\u003e4 to 20 mA\u003c\/strong\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003e0 to 20 mA\u003c\/strong\u003e\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e4 to 20 mA Enhanced\u003c\/strong\u003e (with open-wire fault detection)\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Filter Response:\u003c\/strong\u003e \u003cstrong\u003e200 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Input Circuit Current:\u003c\/strong\u003e \u003cstrong\u003e65 mA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e \u003cstrong\u003e120 mA\u003c\/strong\u003e @ +5VDC (backplane); \u003cstrong\u003e65 mA\u003c\/strong\u003e @ +24VDC isolated (plus current loop current(s))\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 12 binary bits (A\/D converter)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Accuracy:\u003c\/strong\u003e ±0.25% of full scale @ 25°C; ±0.5% @ 0-60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 15 milliseconds (all 16 channels)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cstrong\u003e0°C to 60°C\u003c\/strong\u003e (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLED Indicators\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMODULE OK LED:\u003c\/strong\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eON:\u003c\/strong\u003e Status OK, module configured\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOFF:\u003c\/strong\u003e No backplane power or watchdog timeout\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRapid flashing:\u003c\/strong\u003e Configuration data not received from CPU\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSlow flashes then OFF:\u003c\/strong\u003e Failed power-up diagnostics or code execution error\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser Supply LED:\u003c\/strong\u003e Indicates external 24 VDC supply is within specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCore Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16-channel high-density current input\u003c\/li\u003e\n\u003cli\u003eThree configurable input ranges including Enhanced for open-wire detection\u003c\/li\u003e\n\u003cli\u003eHigh and low alarm limits on all ranges\u003c\/li\u003e\n\u003cli\u003e4-20 mA Enhanced range detects open-wire faults (4 mA to 0 mA)\u003c\/li\u003e\n\u003cli\u003eModule status and external power status reporting to CPU\u003c\/li\u003e\n\u003cli\u003eBuilt-in protection allows 32 mA fast blow fuse per channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4-20 mA process transmitter monitoring\u003c\/li\u003e\n\u003cli\u003eMulti-point current loop data acquisition\u003c\/li\u003e\n\u003cli\u003eOpen-wire fault detection in critical loops\u003c\/li\u003e\n\u003cli\u003eProcess variable trending and logging\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 4-20 mA and 4-20 mA Enhanced?\u003c\/strong\u003e\u003cbr\u003e\nA: The \u003cstrong\u003e4-20 mA Enhanced\u003c\/strong\u003e range allows setting a low alarm limit down to \u003cstrong\u003e0 mA\u003c\/strong\u003e, providing \u003cstrong\u003eopen-wire fault detection\u003c\/strong\u003e. Standard 4-20 mA range cannot detect open-wire conditions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How much external 24V power is required?\u003c\/strong\u003e\u003cbr\u003e\nA: The module requires \u003cstrong\u003e65 mA\u003c\/strong\u003e from the user-supplied +24 VDC isolated supply, plus the current loop current(s) from all active channels.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the RX3i rack before installation.\u003c\/li\u003e\n\u003cli\u003eInsert the IC694ALG223 into any I\/O slot of the RX3i universal backplane.\u003c\/li\u003e\n\u003cli\u003eConnect 4-20 mA field signals to the input terminals.\u003c\/li\u003e\n\u003cli\u003eProvide external +24 VDC isolated power supply.\u003c\/li\u003e\n\u003cli\u003eConfigure channels, ranges, and alarm limits via RX3i programming software.\u003c\/li\u003e\n\u003cli\u003eVerify MODULE OK and User Supply LEDs indicate proper operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor voltage input, use \u003cstrong\u003eIC694ALG222\u003c\/strong\u003e (16-channel voltage input).\u003c\/li\u003e\n\u003cli\u003eFor universal input (TC\/RTD\/Voltage\/Current), use \u003cstrong\u003eIC695ALG600\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eFor 8-channel current input, use \u003cstrong\u003eIC694ALG221\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eInstall 32 mA fast blow fuses externally for channel protection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53833742385336,"sku":"IC694ALG223","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC694ALG223r180.png?v=1785480283","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-analog-input-module-ic694alg223","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}