{"product_id":"ge-fanuc-cpu-processors-pacsystems-rx3i-ic695cpl410","title":"GE Fanuc CPU Processors PACSystems RX3i IC695CPL410","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695CPL410\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC695CPL410\u003c\/strong\u003e Controller Module, operates as a dedicated hardware component for central processing and logic execution within PACSystems RX3i platforms. The unit executes deterministic automation routines, coordinates continuous system diagnostic loops, and manages data routing across the underlying rack backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695CPL410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e140 mm x 135 mm x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0-60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.0 A at 3.3 VDC, 1.2 A at 5.1 VDC from backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial AMD G-Series Quad Core 1.2 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmbedded Memory\u003c\/td\u003e\n\u003ctd\u003e64 MB user memory, 64 MB non-volatile flash memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Interfaces\u003c\/td\u003e\n\u003ctd\u003e1 x RJ-45 Ethernet, 1 x USB Type-A, 1 x RS-232, 1 x RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Ethernet Network and Backplane Bus Performance\u003c\/h3\u003e\n\u003cp\u003eThe hardware platform utilizes an optimized processing layer to maximize backplane bus communication velocity across complex automation topologies. It executes simultaneous logic rungs while maintaining complete firmware flash compatibility with modern RX3i discrete, analog, and specialty modules. Through its integrated RJ-45 interface, the module provides embedded connectivity to Profinet and EtherNet\/IP deterministic networks, sustaining high data throughput and precise scan sync timings during heavy system expansions under demanding I\/O density scaling profiles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is hot-swapping or RIUP (Removal and Insertion Under Power) supported for this primary controller?\u003c\/p\u003e\n\u003cp\u003eA: No. Prior to extracting or inserting the processor module, the upstream rack power supply and all connected field communication loops must be completely isolated. Pulling the primary processing unit while the backplane bus is energized will cause immediate system halt states and risks data corruption within the volatile memory layers.\u003c\/p\u003e\n\u003cp\u003eQ: How is application memory retention managed during a complete facility power loss?\u003c\/p\u003e\n\u003cp\u003eA: The hardware utilizes internal non-volatile flash memory to store the compiled active project configuration, user logic, and system registers. Upon power restoration, the hardware automatically transfers the stored program data back into working RAM, executing a clean cold-start sequence without requiring external backup battery modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the processor module into the dedicated CPU slot on the main universal backplane rack, checking that both the top and bottom retention tabs click firmly into place.\u003c\/li\u003e\n\u003cli\u003eUse double-shielded Category 6a cables for all network runs terminating at the embedded RJ-45 port to protect communication streams from heavy industrial electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eConnect a low-impedance copper ground strap from the central chassis earth stud directly to the enclosure ground bar to effectively divert high-frequency interference.\u003c\/li\u003e\n\u003cli\u003eProvide at least 100 mm of clear vertical space above and below the module chassis to facilitate unobstructed passive convection airflow and prevent heat pocket formation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53523829948600,"sku":"IC695CPL410","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC695CPL410_2_1.jpg?v=1780044839","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-cpu-processors-pacsystems-rx3i-ic695cpl410","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}