{"product_id":"ge-fanuc-ic200alg266-versamax-analog-input-module","title":"GE Fanuc IC200ALG266 VersaMax Analog Input Module","description":"\u003ch3\u003eGE Fanuc IC200ALG266 VersaMax Analog Input Module — 15-Channel, 15-Bit, Current, TUV Approved\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eIC200ALG266\u003c\/strong\u003e is a \u003cstrong\u003e15-channel, 15-bit analog current input module\u003c\/strong\u003e from the GE Fanuc VersaMax series. It provides fifteen \u003cstrong\u003esingle-ended current inputs\u003c\/strong\u003e (4–20 mA default, 0–20 mA jumper-configurable) with a shared common return, all in one group. The module is \u003cstrong\u003eTUV approved for SIL2 applications\u003c\/strong\u003e and features active input protection circuitry that limits current to 40 mA max if accidentally connected to +24V field power.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc \/ Emerson Automation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e VersaMax\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Analog Current Input Module\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 15 single-ended, one group\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 15-bit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Range (Default):\u003c\/strong\u003e 4–20 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Range (Jumper):\u003c\/strong\u003e 0–20 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 100 Ω minimum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 7.5 ms (all channels)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFilter Response:\u003c\/strong\u003e 24 Hz ±20%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 100 mA max from +5V bus\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExternal Power:\u003c\/strong\u003e Not required (backplane powered)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 250 VAC continuous; 1500 VAC for 1 minute\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e OK (green when configured \u0026amp; recognized)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTUV Approved:\u003c\/strong\u003e Yes, for SIL2 \/ GMR safety-relevant systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Active circuit limits input current to 40 mA max on +24V accidental connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDiagnostics \u0026amp; Faults\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoss of Internal Power:\u003c\/strong\u003e Reported for field-side circuits\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOpen Wire Fault:\u003c\/strong\u003e Reported per channel in 4–20 mA mode\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInternal Hardware Fault:\u003c\/strong\u003e A\/D conversion malfunction detection; 3 consecutive failures stop scanning, OK LED off — requires power cycle or replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAll VersaMax carriers and CPU\/NIUs\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eNot compatible with DeviceNet NIU (IC200DBI001)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eMount on compatible VersaMax I\/O carrier (IC200CHSxxx series).\u003c\/li\u003e\n  \u003cli\u003eConfigure range jumper: \u003cstrong\u003eno jumper = 4–20 mA\u003c\/strong\u003e; \u003cstrong\u003ejumper installed = 0–20 mA\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eWire 15 single-ended current inputs; all channels share a common return.\u003c\/li\u003e\n  \u003cli\u003eEnsure transmitter power is supplied externally — module does not power field devices.\u003c\/li\u003e\n  \u003cli\u003ePower on and verify \u003cstrong\u003eOK LED\u003c\/strong\u003e illuminates green.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is IC200ALG266 voltage or current input?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eCurrent input (4–20 mA \/ 0–20 mA).\u003c\/strong\u003e Note: Some third-party sources incorrectly list it as voltage (-10V to +10V); that description applies to IC200ALG265. Always verify with official GFK-2526 manual.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does it need external power?\u003c\/strong\u003e\u003cbr\u003e\nA: No. The module is powered entirely from the +5V backplane bus (100 mA max). However, \u003cstrong\u003eexternal transmitter power must be supplied separately\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What happens on CPU stop or communication loss?\u003c\/strong\u003e\u003cbr\u003e\nA: Software-configurable: outputs can hold \u003cstrong\u003elast state\u003c\/strong\u003e or go to \u003cstrong\u003edefault state\u003c\/strong\u003e for safe startup.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is it suitable for safety systems?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. The IC200ALG266 is \u003cstrong\u003eTUV approved for SIL2\u003c\/strong\u003e and can be used in the safety-relevant portion of a GMR (Genius Modular Redundancy) system.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What if I accidentally wire +24V to an input?\u003c\/strong\u003e\u003cbr\u003e\nA: The module's active protection circuit limits input current to \u003cstrong\u003e40 mA max\u003c\/strong\u003e, protecting the sense resistors from damage.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e15-channel current input (TUV\/SIL2):\u003c\/strong\u003e IC200ALG266\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e15-channel voltage input (TUV\/SIL2):\u003c\/strong\u003e IC200ALG265\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e15-channel current input (non-TUV):\u003c\/strong\u003e IC200ALG264\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e15-channel voltage input (non-TUV):\u003c\/strong\u003e IC200ALG263\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e8-channel current\/voltage (12-bit):\u003c\/strong\u003e IC200ALG260\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlways verify:\u003c\/strong\u003e Current vs. voltage, TUV requirement, and NIU compatibility before ordering\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Buy from Us?\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e100% Genuine GE Fanuc \/ Emerson product\u003c\/li\u003e\n  \u003cli\u003eBrand new, factory-sealed\u003c\/li\u003e\n  \u003cli\u003e12-month warranty\u003c\/li\u003e\n  \u003cli\u003eFast global shipping\u003c\/li\u003e\n  \u003cli\u003eBulk pricing available\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cem\u003eReference: GE Fanuc VersaMax Analog I\/O Modules User Manual GFK-2526. Specifications subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53720455315640,"sku":"IC200ALG266","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC200ALG266_2_r180.png?v=1783498773","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-ic200alg266-versamax-analog-input-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}