{"product_id":"ge-fanuc-ic660bba025-genius-i-o-thermocouple-input-block","title":"GE Fanuc IC660BBA025 Genius I\/O Thermocouple Input Block","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBA025 (IC660BBA025) functions as a specialized, 6-channel thermocouple input block within the GE Fanuc Genius I\/O ecosystem. This intelligent distributed module interfaces directly with Type J, K, T, E, R, S, and B thermocouples, as well as low-level mV signals. Designed for high-heat environments such as blast furnaces, glass manufacturing, and plastic injection molding, the IC660BBA025 eliminates the need for expensive thermocouple extension wire runs by digitizing signals at the point of measurement. We provide this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, ensuring factory-sealed reliability and precise thermal calibration for your critical control loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBA025 features high-resolution A\/D conversion and integrated cold junction compensation (CJC) for superior measurement stability.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc \/ Emerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC660BBA025\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGenius I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Isolated Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermocouple Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJ, K, T, E, R, S, B, and +\/-50mV or +\/-100mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 deg C or 1 microvolt\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCold Junction Comp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic (Onboard thermistor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.5 ms per enabled channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500V Peak between Genius bus and inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115 VAC \/ 230 VAC or 24\/48 VDC (Version dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLocalized Signal Conditioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy mounting the IC660BBA025 near the process, engineers significantly reduce signal degradation and EMI pickup associated with long-distance millivolt wiring. The block converts weak analog signals into robust digital packets for transmission over the Genius bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSophisticated Fault Profiling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module continuously monitors for \"Open Wire\" conditions and \"Out of Range\" values. It identifies a failed thermocouple immediately, allowing the control system to trigger safe-state logic or switch to a secondary sensor without manual intervention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis block utilizes advanced hardware filtering to reject 50\/60 Hz line noise, which often plagues temperature sensors located near heavy industrial motors or heaters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Commissioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe terminal assembly detaches from the electronic module. This allows technicians to perform field wiring and testing before the electronics are even installed, accelerating the overall plant startup schedule.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a separate compensation box for the cold junction?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC660BBA025 includes an integrated thermistor at the terminal assembly to perform automatic cold junction compensation. This ensures the digitized value reflects the absolute temperature of the process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix thermocouple types on a single block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe configuration typically applies to all six channels globally. However, the block supports a mV mode, which offers flexibility for non-standard sensors if scaled correctly in the PLC logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the \"Open Wire\" detection work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe block sources a tiny current through the thermocouple. If the sensor breaks or the wire detaches, the circuit opens, and the block immediately transmits a diagnostic \"Open Wire\" fault code over the Genius network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this block compatible with the 90-30 or 90-70 PLC series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC660BBA025 integrates with any GE Fanuc CPU equipped with a Genius Bus Controller (GBC), including legacy 90-series and modern PACSystems RX3i controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53447308509368,"sku":"IC660BBA025","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC660BBA025_3.jpg?v=1778232089","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-ic660bba025-genius-i-o-thermocouple-input-block","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}