{"product_id":"ge-fanuc-ic693cpu351-cpu-processors-series-90-30","title":"GE Fanuc IC693CPU351 CPU Processors Series 90-30","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693CPU351\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693CPU351\u003c\/strong\u003e Controller Module, operates as a dedicated hardware component for central processing and deterministic logic execution within Series 90-30 platforms. The hardware handles real-time bit transformations, coordinates memory mapping sequences, and executes background diagnostic sweeps across the active backplane architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693CPU351\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 mm x 115 mm x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0-60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e890 mA at 5 VDC from baseplate power rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003e80386SX running at 25 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Logic Memory\u003c\/td\u003e\n\u003ctd\u003e240 KB non-volatile user RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-Slot Capacity\u003c\/td\u003e\n\u003ctd\u003eMounts strictly in Slot 1 of 5-slot or 10-slot baseplates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network and Backplane Bus Performance\u003c\/h3\u003e\n\u003cp\u003eThe hardware platform incorporates specialized internal registers optimized to accelerate backplane bus communication velocity across localized and expansion structures. It maintains strict firmware flash compatibility lines with legacy Series 90-30 discrete and analog I\/O hardware, minimizing memory lookup latency during scan transitions. The processor architecture facilitates coordinated data handshakes required for I\/O density scaling profiles when linked with network coprocessors operating on parallel Profinet or EtherNet\/IP deterministic networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC693CPU351 module be removed or inserted while the baseplate is powered?\u003c\/p\u003e\n\u003cp\u003eA: No. Hot-swapping or removal under power is not supported. The main power supply module must be fully isolated before extracting or inserting the controller. Attempting an online swap will interrupt backplane bus communication velocity control loops and risks permanent logical state corruption.\u003c\/p\u003e\n\u003cp\u003eQ: How is the volatile user RAM application preserved during system power outages?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on the standard lithium battery assembly connected to the adjacent power supply module via the baseplate power rails. If battery voltage drops beneath the operational threshold, the stored register variables and user configuration logic will clear upon a prolonged facility power isolation event.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the controller module exclusively into Slot 1 of the baseplate chassis, ensuring the top and bottom retention teeth fully clip onto the chassis rail.\u003c\/li\u003e\n\u003cli\u003eRoute all serial or peripheral communications cables in dedicated wire ways segregated from 230 VAC \/ 480 VAC motor control lines to limit capacitive cross-talk.\u003c\/li\u003e\n\u003cli\u003eConnect the primary baseplate grounding stud directly to the enclosure master earth bar using a low-impedance copper braid.\u003c\/li\u003e\n\u003cli\u003eMaintain a standard clearance of 100 mm above and below the rack framing to facilitate proper passive convection cooling paths.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53523893780664,"sku":"IC693CPU351","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC693CPU351_2.jpg?v=1780046684","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-ic693cpu351-cpu-processors-series-90-30","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}