{"product_id":"ge-fanuc-ic693cpu352-series-90-30-cpu-processor","title":"GE Fanuc IC693CPU352 Series 90-30 CPU Processor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693CPU352\u003c\/strong\u003e serves as the primary \u003cstrong\u003eIC693CPU352\u003c\/strong\u003e CPU Processor utilized to execute discrete and analog logic sequencing across Series 90-30 programmable logic controller platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693CPU352\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e132 mm x 36 mm x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e890 mA at 5 VDC (from backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003eEmbedded High-Speed Microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e240K Bytes (RAM and Flash options)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e2048 Discrete Inputs, 2048 Discrete Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Capacity\u003c\/td\u003e\n\u003ctd\u003e1024 Inputs, 512 Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Speed\u003c\/td\u003e\n\u003ctd\u003e0.22 ms per 1K Boolean instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Backplane Bus Communication and Firmware Control\u003c\/h3\u003e\n\u003cp\u003eThe processing unit manages localized data transformations via the parallel backplane bus communication velocity architecture embedded in the baseplate chassis. Boolean bit solving registers coordinate with standard peripheral channels to optimize internal I\/O density scaling profiles, keeping thermal gradients within prescribed design limits during multi-rack updates. Operational code handling relies on defined firmware flash compatibility parameters, preventing transmission jitter or clock phase asynchronous drifting when mapping variable tables between the integrated processor RAM and external communication modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC693CPU352 hardware design support online hot-swapping while the baseplate is powered?\u003c\/p\u003e\n\u003cp\u003eA: No. The parallel data traces and power pins on the Series 90-30 backplane interface are not engineered with staggered contact lengths. Live insertion or extraction of this central processor module causes severe transient voltage loops, resulting in system logic corruption or immediate solid-state gate failure.\u003c\/p\u003e\n\u003cp\u003eQ: How does the IC693CPU352 processor handle the retention of user application programs during input supply dropouts?\u003c\/p\u003e\n\u003cp\u003eA: Volatile registers and program structures inside the internal RAM are preserved via a lithium battery cell mounted within the baseplate assembly. If power remains disconnected for extended durations and the battery potential sinks below the minimum nominal threshold, the memory states will reset unless backed up to non-volatile EEPROM storage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eIsolate the main alternating or direct current supply source feeding the Series 90-30 baseplate chassis before attempting installation or removal.\u003c\/li\u003e\n\u003cli\u003eGuide the module into slot 1 of the baseplate, pushing backward firmly until the upper and lower plastic retention clips snap completely into position over the chassis edge.\u003c\/li\u003e\n\u003cli\u003eEstablish a solid mechanical path to earth by bonding the baseplate ground lug to the enclosure ground terminal using a minimum 4 mm2 copper grounding wire.\u003c\/li\u003e\n\u003cli\u003eRoute the communication cables plugged into the front interface away from high-voltage AC motor conductors or switching relays by a minimum distance of 30 cm to suppress inductive cross-talk.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53514741711032,"sku":"IC693CPU352","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC693CPU352_2.jpg?v=1779849816","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-ic693cpu352-series-90-30-cpu-processor","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}