{"product_id":"ge-fanuc-ic693mdl752-32-point-5-12-24vdc-negative-logic-sinking-output-module","title":"GE Fanuc IC693MDL752 32-Point 5\/12\/24VDC Negative Logic (Sinking) Output Module","description":"\u003ch2\u003e\u003cstrong\u003eModule Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693MDL752\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density discrete output module designed for the GE Fanuc Series 90-30 PLC system. This component provides 32 sinking output points, specifically engineered to interface with low-power DC field devices or TTL-level logic circuits. Organized into four isolated groups of eight points each, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693MDL752\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers significant space savings in the PLC rack while maintaining electrical separation between different control circuits.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThis module is versatile, supporting both standard 12\/24VDC industrial voltages and 5VDC TTL applications. Note that current capacities vary significantly based on the operating mode selected.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNegative Logic (Sinking)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Output Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 (Four isolated groups of 8)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Voltage Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5VDC (TTL) and 12 to 24VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTTL Mode Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.75 to 5.25 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Mode Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 to 24 VDC (+20%, -15%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current (TTL Mode)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 mA per point maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current (12\/24V Mode)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5A per point \/ 2.0A per common\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOn-State Voltage Drop\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 VDC (TTL) to 1.5 VDC (Industrial)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time (On\/Off)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 milliseconds maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e260 mA from +5V DC bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual 24-pin Fujitsu connectors (typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 Volts between field side and logic side\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cstrong\u003eOperational and Engineering Notes\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eWhen configuring the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693MDL752\u003c\/strong\u003e, engineers must account for the high-density wiring required by 32 points. Unlike 8 or 16-point modules with screw terminals, this module typically utilizes high-density connectors. It is critical to ensure the external power supply matches the logic levels of the field equipment. Since this is a \"Negative Logic\" module, the PLC completes the circuit to the negative rail (Common), meaning the load must be pre-wired to the positive DC voltage source.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical Application Scenarios\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTTL Interfacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDriving 5V semiconductor logic, microcontrollers, or high-speed electronic gates that require low-current switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Room Panels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManaging large arrays of LED indicator lamps and small annunciators where rack space is limited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy Upgrades:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReplacing multiple low-density modules to free up slots in a Series 90-30 baseplate without changing the field logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix 5V and 24V signals on the same IC693MDL752 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, provided the different voltages are isolated by group. Each of the four groups has its own common, allowing you to run TTL signals on one group and 24VDC on another, assuming proper wiring practices are followed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific fuse for protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is designed for low-current applications. While it has internal protection, it is best practice to use external fuses for each group common terminal, especially when operating in the 12\/24VDC mode at 2.0A per group.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53075085164728,"sku":"IC693MDL752","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC693MDL752.jpg?v=1773971208","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-ic693mdl752-32-point-5-12-24vdc-negative-logic-sinking-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}