{"product_id":"ge-fanuc-ic694mdl231-pacsystems-rx3i-discrete-output-module","title":"GE Fanuc IC694MDL231 PACSystems RX3i Discrete Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694MDL231\u003c\/strong\u003e serves as the primary \u003cstrong\u003eIC694MDL231\u003c\/strong\u003e Discrete Output Module utilized to execute alternating-current load manipulation across PACSystems RX3i platforms. This hardware component provides 8 independent isolated channels designed to switch inductive or resistive field circuits operating within nominal ranges up to 240 VAC. Electrical isolation between the individual channels ensures that transient spikes or wiring anomalies in one external loop do not propagate to adjacent control circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eIC694MDL231\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eGE Fanuc (PACSystems RX3i)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eModule Type\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eAC Isolated Discrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e3.2 cm x 14.1 cm x 11.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e160 mA at 5 VDC via Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e8 (Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e12 to 264 VAC, 47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eOutput Current Rating\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e2.0 A max per channel (subject to derating limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e50 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eOn-state Voltage Drop\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e1.5 VAC max at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eLeakage Current\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e3.0 mA max at 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eI\/O Density Scaling and Control Interconnection\u003c\/h3\u003e\n\u003cp\u003eThe physical configuration features single-slot design optimization to manage I\/O density scaling inside the standard hardware chassis. The component features zero-voltage switching circuitry to limit thermal stress and suppress transient electromagnetic emission steps during cyclic actuation. Onboard status lamps provide visual indexing of output logic registers, aligning system memory states with field operations. This card supports standard firmware flash compatibility protocols across RX3i modules to verify uniform execution timing with the host controller.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this module operate under high-speed switching loops or pulse-width modulation schemes?\u003c\/p\u003e\n\u003cp\u003eA: No. The triac-based solid-state outputs require an alternative current zero-crossing to open the circuit. Turn-on response time is up to 1 ms, and turn-off response time takes up to one-half of an AC cycle, making it unsuitable for high-frequency pulsing networks.\u003c\/p\u003e\n\u003cp\u003eQ: What are the continuous output constraints when multiple channels are energized simultaneously?\u003c\/p\u003e\n\u003cp\u003eA: The current constraints depend on ambient thermal data. At 60 deg C, the total continuous current for the combined 8 channels must not exceed 10.0 A. Exceeding this thermal threshold triggers the thermal derating envelope and degrades output reliability.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFusing Infrastructure\u003c\/strong\u003e: Each isolated channel operates without onboard circuit fuses. External protection devices matching the maximum load curves must be installed in series with each output terminal to protect the internal triacs from overcurrent failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block Separation\u003c\/strong\u003e: Keep AC power distribution wiring separated from low-voltage DC communication or instrument loops within the wire ducts to prevent signal cross-talk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Retention\u003c\/strong\u003e: Align the module with the upper and lower chassis guides before sliding it into the backplane connector. Secure the single-screw latch at the bottom of the front faceplate to ensure ground trace continuity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53512138162360,"sku":"IC694MDL231","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC694MDL231_1.jpg?v=1779785946","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-ic694mdl231-pacsystems-rx3i-discrete-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}