{"product_id":"ge-fanuc-ic694mdl741-digital-output-cards-pacsystems-rx3i","title":"GE Fanuc IC694MDL741 Digital Output Cards PACSystems RX3i","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eConfigured for high-density discrete switching tasks in PACSystems RX3i networks, the \u003cstrong\u003eGE Fanuc IC694MDL741\u003c\/strong\u003e (\u003cstrong\u003eIC694MDL741\u003c\/strong\u003e Discrete Output Module) provides direct physical\/electrical execution. The component provides sixteen independent solid-state output circuits to drive field-side indicators, interposing relays, and low-power actuator circuits based on control data transferred from the central processor.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694MDL741\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 mm x 115 mm x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0-60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e110 mA at 5 VDC from backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 Channels (Sourcing type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e12-24 VDC nominal (10.2 VDC to 30 VDC operating range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Capacity\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point maximum (4.0 A maximum per group\/module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Backplane Bus Performance\u003c\/h3\u003e\n\u003cp\u003eThe hardware structures its electronic output switching block to align with the host rack assembly, maximizing backplane bus communication velocity. The integrated control circuits maintain precise timing profiles across internal logic tracks, securing data validation parameters during high-speed scanning updates. It exhibits strict firmware flash compatibility with contemporary RX3i controllers, allowing full integration across expansive I\/O density scaling configurations alongside parallel Profinet and EtherNet\/IP deterministic networks without introducing communication jitter or channel-to-channel execution delays.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC694MDL741 module support Hot-Swap (RIUP) operations?\u003c\/p\u003e\n\u003cp\u003eA: No. Prior to extracting or inserting this module into the active rack frame, all primary system power supplies and external field excitation loops must be completely isolated. Swapping the component while the backplane is energized can induce localized communication interruptions or cause unexpected fault flags to trip within the master controller registers.\u003c\/p\u003e\n\u003cp\u003eQ: What type of internal overcurrent protection is provided for each channel?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates electronic short-circuit protection and thermal shutdown mechanisms per group. If a specific field load exceeds the 0.5 A limit or undergoes a short-circuit fault, the affected channel block disables its solid-state output switches to safeguard the internal backplane traces from overcurrent damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePosition the module within any standard I\/O slot of the universal backplane, ensuring that the top and bottom physical hooks fully engage the retention rail blocks.\u003c\/li\u003e\n\u003cli\u003eRoute all low-voltage 24 VDC output control paths inside dedicated wire ducts separate from heavy AC power cables or variable-frequency drive connections to avoid electromagnetic noise coupling.\u003c\/li\u003e\n\u003cli\u003eConnect an external, regulated 24 VDC field power source to the designated terminals on the front connector block to supply current to the sourcing output electronics.\u003c\/li\u003e\n\u003cli\u003eVerify that all external inductive loads (such as DC relay coils or solenoid valves) are equipped with external flyback diodes wired in parallel to suppress inductive voltage spikes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53523827720376,"sku":"IC694MDL741","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC694MDL741_3.jpg?v=1780044691","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-ic694mdl741-digital-output-cards-pacsystems-rx3i","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}