{"product_id":"ge-fanuc-ic694mdl940-16-point-relay-output-module","title":"GE Fanuc IC694MDL940 16-Point Relay Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IC694MDL940\u003c\/strong\u003e is a \u003cstrong\u003e16-Point Relay Output Module\u003c\/strong\u003e for the Emerson PACSystems RX3i programmable automation controller platform. It provides \u003cstrong\u003e16 normally open (N.O.) relay contacts\u003c\/strong\u003e organized in \u003cstrong\u003e4 groups of 4 outputs each\u003c\/strong\u003e, supporting both AC and DC loads for versatile industrial control applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e IC694MDL940\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PACSystems RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Relay Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Points:\u003c\/strong\u003e \u003cstrong\u003e16\u003c\/strong\u003e normally open (N.O.) contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Groups:\u003c\/strong\u003e \u003cstrong\u003e4 groups\u003c\/strong\u003e of 4 outputs each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage (DC):\u003c\/strong\u003e \u003cstrong\u003e5–30 VDC\u003c\/strong\u003e (nominal 24 VDC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage (AC):\u003c\/strong\u003e \u003cstrong\u003e5–250 VAC\u003c\/strong\u003e at 47–63 Hz (nominal 120\/240 VAC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current per Point:\u003c\/strong\u003e \u003cstrong\u003e2 Amps\u003c\/strong\u003e (pilot duty)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current per Group:\u003c\/strong\u003e \u003cstrong\u003e4 Amps\u003c\/strong\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Load:\u003c\/strong\u003e \u003cstrong\u003e10 mA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Inrush Current:\u003c\/strong\u003e \u003cstrong\u003e5 Amps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u003cstrong\u003e15 ms\u003c\/strong\u003e (typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e \u003cstrong\u003e7 mA\u003c\/strong\u003e @ 5VDC (all outputs on); \u003cstrong\u003e24 mA\u003c\/strong\u003e @ relay 135V bus (all outputs on)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e\n  \u003cul\u003e\n    \u003cli\u003eField to Backplane: \u003cstrong\u003e250 VAC continuous; 1500 VAC for 1 minute\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eChannel to Channel: \u003cstrong\u003e250 VAC continuous; 1500 VAC for 1 minute\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e 16 status LEDs (one per channel)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cstrong\u003e0°C to 60°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCore Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 relay outputs with isolated N.O. contacts\u003c\/li\u003e\n\u003cli\u003eSupports both AC (5-250V) and DC (5-30V) loads\u003c\/li\u003e\n\u003cli\u003e4 isolated groups of 4 outputs each\u003c\/li\u003e\n\u003cli\u003eIndividual LED status indication for each channel\u003c\/li\u003e\n\u003cli\u003eNo built-in fuse — external fuse protection recommended\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC\/DC relay-based device control\u003c\/li\u003e\n\u003cli\u003eMotor starter and contactor control\u003c\/li\u003e\n\u003cli\u003eAlarm and signaling systems\u003c\/li\u003e\n\u003cli\u003eIsolated output switching for safety circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum load per group?\u003c\/strong\u003e\u003cbr\u003e\nA: The maximum load per group of 4 outputs is \u003cstrong\u003e4 Amps\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does the module have built-in fuses?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e The IC694MDL940 does not have built-in fuses. Users should install \u003cstrong\u003eexternal fuses\u003c\/strong\u003e for channel protection.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor 8-point relay output, consider \u003cstrong\u003eIC694MDL930\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eFor solid-state DC output, use \u003cstrong\u003eIC694MDL740\u003c\/strong\u003e or \u003cstrong\u003eIC694MDL741\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eInstall external fuses (2A recommended) for each output channel.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53833795502264,"sku":"IC694MDL940","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC694MDL940_2_03fd8c37-5bdb-4232-9e9b-52ac429d7f21.png?v=1785480285","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-ic694mdl940-16-point-relay-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}