{"product_id":"ge-fanuc-ic695alg728-rx3i-analog-output-module","title":"GE Fanuc IC695ALG728 RX3i Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695ALG728\u003c\/strong\u003e is an \u003cstrong\u003e8-Channel, Non-Isolated Analog Output Module\u003c\/strong\u003e for the \u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e platform. It delivers precise voltage and current signals to field devices and features integrated \u003cstrong\u003eHART Protocol Version 5.0\u003c\/strong\u003e communication, enabling direct digital interfacing with smart transmitters and valve positioners. Each of the eight channels is individually configurable via software—no jumpers required—making it ideal for process control, batch automation, and SCADA integration.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e8 Configurable Output Channels:\u003c\/strong\u003e Voltage or current, individually selectable per channel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHART Protocol v5.0:\u003c\/strong\u003e Built-in dual HART modems (4 channels per modem) for smart device communication\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Resolution:\u003c\/strong\u003e Up to 15.9 bits for voltage and current outputs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSoftware-Configurable:\u003c\/strong\u003e No physical jumpers; all settings managed through programming software\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e Channel-level alarms, fault reporting, latching, and configurable clamp\/bias limits\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAuto-Calibration:\u003c\/strong\u003e Maintains accuracy across the operating temperature range\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHot-Swappable:\u003c\/strong\u003e Supports insertion and removal under power when used with RX3i Universal Backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc \/ Emerson Automation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PACSystems RX3i\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e IC695ALG728\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Output Module with HART\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 8 non-isolated, single-ended\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Output Ranges:\u003c\/strong\u003e 0 to +10 VDC, –10 to +10 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Output Ranges:\u003c\/strong\u003e 0–20 mA, 4–20 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003e±10 VDC: \u003cstrong\u003e15.9 bits\u003c\/strong\u003e\n\u003c\/li\u003e\n      \u003cli\u003e0–10 VDC: \u003cstrong\u003e14.9 bits\u003c\/strong\u003e\n\u003c\/li\u003e\n      \u003cli\u003e0–20 mA: \u003cstrong\u003e15.9 bits\u003c\/strong\u003e\n\u003c\/li\u003e\n      \u003cli\u003e4–20 mA: \u003cstrong\u003e15.6 bits\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCalibrated Accuracy:\u003c\/strong\u003e ±0.15% full scale at 25°C; ±0.30% full scale at 60°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAnalog Update Rate:\u003c\/strong\u003e 8 ms (all channels, without HART); 16 ms (all channels, with HART enabled)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Settling Time:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eVoltage: 2 ms (0–95%)\u003c\/li\u003e\n      \u003cli\u003eCurrent (no HART): 23 ms (0–95%)\u003c\/li\u003e\n      \u003cli\u003eCurrent (with HART): 70 ms (0–95%)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Output Load:\u003c\/strong\u003e 850 Ω (current mode)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Voltage Load:\u003c\/strong\u003e 2 kΩ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Overvoltage Protection:\u003c\/strong\u003e –30 V for 60 s, +30 V for 1 hr (current outputs only)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 2550 VDC (field to backplane, 1 second)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eData Format:\u003c\/strong\u003e Configurable as IEEE 32-bit floating point or 16-bit integer in 32-bit field\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHART Modems:\u003c\/strong\u003e 2 internal modems (4 channels multiplexed per modem)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHART Scan Time (typical):\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003e1 HART channel per group: ~0.7 s\u003c\/li\u003e\n      \u003cli\u003e2 HART channels per group: ~1.9 s\u003c\/li\u003e\n      \u003cli\u003e3 HART channels per group: ~3.0 s\u003c\/li\u003e\n      \u003cli\u003e4 HART channels per group: ~4.0 s\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBackplane Power:\u003c\/strong\u003e 380 mA max @ 3.3 VDC (with HART enabled)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExternal Power Supply:\u003c\/strong\u003e 19.2–30 VDC (24 V nominal), 190–250 mA max\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 7.25 W max (at Vuser = 24 VDC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e ~127 × 64 × 46 mm (5.0 × 2.5 × 1.8 in)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~0.20 kg\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommercial Status:\u003c\/strong\u003e Active\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eRelated RX3i Analog Output Modules\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIC695ALG704\u003c\/strong\u003e — 4-Channel Isolated Analog Output (no HART)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIC695ALG708\u003c\/strong\u003e — 8-Channel Non-Isolated Analog Output (no HART)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIC695ALG728\u003c\/strong\u003e — 8-Channel Non-Isolated Analog Output \u003cstrong\u003ewith HART\u003c\/strong\u003e ← \u003cstrong\u003eThis Item\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Remove system power before installing or removing the module to prevent damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Selection:\u003c\/strong\u003e Install the IC695ALG728 into any available slot of an RX3i Universal Backplane (local CPU rack or remote I\/O rack).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExternal Power:\u003c\/strong\u003e Connect a regulated 24 VDC (19.2–30 VDC) external power supply to the module's power terminals. This supply is \u003cstrong\u003erequired\u003c\/strong\u003e for operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Block:\u003c\/strong\u003e Use the removable terminal block (IC695TBBxxx \/ IC695TBBOxxx) for field wiring. Ensure the terminal block is fully seated; the module includes a detector switch that disables outputs if the block is missing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eVoltage outputs: Connect load between VOUT and common (COM).\u003c\/li\u003e\n      \u003cli\u003eCurrent outputs: Connect load between IOUT and common (COM).\u003c\/li\u003e\n      \u003cli\u003eHART channels: Must be configured in 4–20 mA range. Connect HART communicator across the loop resistor or at the field device.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Follow RX3i system grounding guidelines (GFK-2314) to minimize noise and ensure safety.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Use PAC Machine Edition (PME) or Proficy ME to configure each channel's range, data format, alarms, and HART settings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Monitor the module OK LED and individual channel status LEDs for fault diagnosis.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHART Requirement:\u003c\/strong\u003e Choose IC695ALG728 only if you need HART communication with smart field devices. For standard analog outputs without HART, the IC695ALG708 (8-channel) or IC695ALG704 (4-channel isolated) may be more cost-effective.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e The IC695ALG728 provides \u003cstrong\u003enon-isolated\u003c\/strong\u003e channels. If channel-to-channel or channel-to-backplane isolation is required, consider the IC695ALG704 instead.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExternal Power:\u003c\/strong\u003e Ensure your panel has a dedicated 24 VDC supply available. The module cannot operate from backplane power alone.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoad Impedance:\u003c\/strong\u003e Verify that your field devices present ≤ 850 Ω load in current mode. High-impedance voltage loads (\u0026gt;2 kΩ) are required for voltage outputs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e For installations where ambient temperature approaches 60°C, account for the ±0.30% FS accuracy degradation in your control loop design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: Does the IC695ALG728 require an external power supply?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eYes.\u003c\/strong\u003e The module requires an external 19.2–30 VDC supply (24 V nominal, up to 250 mA) in addition to backplane power. It cannot operate from backplane power alone.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can all eight channels use HART simultaneously?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. The module has two internal HART modems, each serving four channels. All eight channels can be configured for 4–20 mA with HART communication active.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What is the difference between IC695ALG728 and IC695ALG708?\u003c\/strong\u003e\u003cbr\u003e\nA: The IC695ALG708 is an 8-channel non-isolated analog output module \u003cstrong\u003ewithout\u003c\/strong\u003e HART. The IC695ALG728 adds \u003cstrong\u003eHART Protocol Version 5.0\u003c\/strong\u003e with dual internal modems. Both share the same voltage\/current ranges and channel count.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: Can I mix voltage and current outputs on the same module?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. Each channel is independently configurable for voltage (±10V or 0–10V) or current (0–20mA or 4–20mA) via software configuration.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: What happens if the terminal block is removed while the system is running?\u003c\/strong\u003e\u003cbr\u003e\nA: The module includes a terminal block detector switch. If the block is removed, the module disables all outputs to prevent uncontrolled signals to the field.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ6: What is the warranty period?\u003c\/strong\u003e\u003cbr\u003e\nA: We provide a standard \u003cstrong\u003e12-month warranty\u003c\/strong\u003e for all new and original GE Fanuc \/ Emerson products.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53833898623160,"sku":"IC695ALG728","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC695ALG728_fd98e3e7-5851-4e36-b1cf-5369a0dc31e9.png?v=1785480114","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-ic695alg728-rx3i-analog-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}