{"product_id":"ge-fanuc-ic695pbm300-rx3i-profibus-dp-master-module","title":"GE Fanuc IC695PBM300 RX3i Profibus DP Master Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IC695PBM300\u003c\/strong\u003e is a \u003cstrong\u003ePROFIBUS-DP Master Module\u003c\/strong\u003e for the Emerson PACSystems RX3i programmable automation controller platform. It enables the RX3i controller to act as a \u003cstrong\u003eDP-Master Class 1\u003c\/strong\u003e on a PROFIBUS-DP network, managing up to \u003cstrong\u003e125 slave devices\u003c\/strong\u003e with deterministic high-speed communication for distributed control systems.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e IC695PBM300\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PACSystems RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e PROFIBUS-DP Master Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported DP Slaves:\u003c\/strong\u003e Up to \u003cstrong\u003e125 slaves\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Size per Slave:\u003c\/strong\u003e Up to \u003cstrong\u003e244 bytes input\u003c\/strong\u003e \/ \u003cstrong\u003e244 bytes output\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal I\/O Capacity:\u003c\/strong\u003e \u003cstrong\u003e3,584 bytes input\u003c\/strong\u003e \/ \u003cstrong\u003e3,584 bytes output\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Baud Rates:\u003c\/strong\u003e \u003cstrong\u003e9.6 k, 19.2 k, 93.75 k, 187.5 k, 500 k, 1.5 M, 3 M, 6 M, 12 M\u003c\/strong\u003e bps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e DP, DP-V1 (Read\/Write, Alarms), Sync\/Freeze modes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Port:\u003c\/strong\u003e 1 × RS-485 PROFIBUS Master port (9-pin Sub-D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e ~\u003cstrong\u003e440 mA\u003c\/strong\u003e @ 3.3 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cstrong\u003e0°C to 60°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Requirement:\u003c\/strong\u003e \u003cstrong\u003e1 slot\u003c\/strong\u003e in RX3i universal backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swap Capability:\u003c\/strong\u003e Yes (in non-hazardous zones)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Upgrade:\u003c\/strong\u003e Via host RX3i CPU using WinLoader utility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e \u003cstrong\u003e0.141 kg\u003c\/strong\u003e (141g)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Requirements:\u003c\/strong\u003e Machine Edition Logic Developer v5.0 or later\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU Firmware:\u003c\/strong\u003e Version 2.9 or later required\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCore Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDP-Master Class 1 for up to 125 PROFIBUS-DP slave devices\u003c\/li\u003e\n\u003cli\u003eSupports all standard PROFIBUS baud rates from 9.6 kbit\/s to 12 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eDP-V1 read\/write and alarm messaging for intelligent device integration\u003c\/li\u003e\n\u003cli\u003eSync and Freeze modes for synchronized multi-device control\u003c\/li\u003e\n\u003cli\u003eComprehensive diagnostics: slave status array, network counters, diagnostic addresses\u003c\/li\u003e\n\u003cli\u003eHot-swappable for online maintenance\u003c\/li\u003e\n\u003cli\u003eFirmware upgradeable via WinLoader without module removal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePROFIBUS-DP network integration with RX3i PACSystems\u003c\/li\u003e\n\u003cli\u003eDistributed I\/O control in manufacturing automation\u003c\/li\u003e\n\u003cli\u003eVariable frequency drive (VFD) control via PROFIBUS\u003c\/li\u003e\n\u003cli\u003eProcess instrumentation and smart device integration\u003c\/li\u003e\n\u003cli\u003eRetrofit of legacy PROFIBUS networks into RX3i architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the IC695PBM300 a CPU?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e The IC695PBM300 is a \u003cstrong\u003ecommunication interface module\u003c\/strong\u003e, not a processor. It occupies one backplane slot and is programmed by the host RX3i CPU.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between IC695PBM300-BA, -CC, and -EC?\u003c\/strong\u003e\u003cbr\u003e\nA: These are different hardware\/firmware revisions. The \u003cstrong\u003e-CC\u003c\/strong\u003e and \u003cstrong\u003e-EC\u003c\/strong\u003e versions include enhanced features and firmware improvements. Verify compatibility with your application before ordering.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum cable length?\u003c\/strong\u003e\u003cbr\u003e\nA: At \u003cstrong\u003e12 Mbit\/s\u003c\/strong\u003e: 100 m; at \u003cstrong\u003e1.5 Mbit\/s\u003c\/strong\u003e: 200 m; at \u003cstrong\u003e93.75 kbit\/s\u003c\/strong\u003e: 1,200 m (per PROFIBUS EN 50170).\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the RX3i rack (or use hot-swap in non-hazardous zones).\u003c\/li\u003e\n\u003cli\u003eInsert the IC695PBM300 into any slot of the RX3i universal backplane.\u003c\/li\u003e\n\u003cli\u003eConnect the PROFIBUS-DP cable to the 9-pin Sub-D connector.\u003c\/li\u003e\n\u003cli\u003eInstall termination resistors at both ends of the PROFIBUS network.\u003c\/li\u003e\n\u003cli\u003eConfigure slave device parameters via Machine Edition software.\u003c\/li\u003e\n\u003cli\u003eVerify network communication using module status LEDs.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor PROFINET networks, consider \u003cstrong\u003eIC695PNC001\u003c\/strong\u003e instead.\u003c\/li\u003e\n\u003cli\u003eVerify all PROFIBUS slave devices support the selected baud rate.\u003c\/li\u003e\n\u003cli\u003eEnsure CPU firmware is version 2.9 or later.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair PROFIBUS cable for reliable communication.\u003c\/li\u003e\n\u003cli\u003eEnable termination only at the two electrical ends of the network segment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53833706307768,"sku":"IC695PBM300","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC695PBM300_67ddbf6a-3403-428a-b29b-5867585399d6.png?v=1785480347","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-ic695pbm300-rx3i-profibus-dp-master-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}