{"product_id":"ge-fanuc-ic695psa040-rx3i-40-watt-power-supply-module","title":"GE Fanuc IC695PSA040 RX3i 40-Watt Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IC695PSA040\u003c\/strong\u003e is a \u003cstrong\u003e40-Watt Power Supply Module\u003c\/strong\u003e for the Emerson PACSystems RX3i programmable automation controller platform. It provides \u003cstrong\u003e+5.1 VDC, +24 VDC relay output, and +3.3 VDC internal power\u003c\/strong\u003e from a wide-range AC\/DC input, designed for single-module installation in the RX3i universal backplane.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e IC695PSA040\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PACSystems RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e AC\/DC Power Supply Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e \u003cstrong\u003e85–264 VAC\u003c\/strong\u003e or \u003cstrong\u003e100–300 VDC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Power:\u003c\/strong\u003e \u003cstrong\u003e40 Watts\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltages:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e+5.1 VDC:\u003c\/strong\u003e Standard DC output for system devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+24 VDC:\u003c\/strong\u003e Relay output for output relay modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+3.3 VDC:\u003c\/strong\u003e Internal use for IC695 series RX3i modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Size:\u003c\/strong\u003e \u003cstrong\u003e14–22 AWG\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Current Rating:\u003c\/strong\u003e \u003cstrong\u003e6 Amps\u003c\/strong\u003e maximum per terminal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlots Required:\u003c\/strong\u003e \u003cstrong\u003e2 slots\u003c\/strong\u003e in RX3i universal backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003cstrong\u003eNot supported\u003c\/strong\u003e (cannot be used with other RX3i power supplies in redundancy mode)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaisy Chain:\u003c\/strong\u003e Supports up to \u003cstrong\u003e4 PSA040 modules\u003c\/strong\u003e for additional capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower LED (Green):\u003c\/strong\u003e Backplane powered\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower LED (Amber):\u003c\/strong\u003e Power switch off\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP\/S Fault (Red):\u003c\/strong\u003e Power failure, insufficient voltage to backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver Temperature (Amber):\u003c\/strong\u003e Approaching\/exceeding maximum operating temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload (Amber):\u003c\/strong\u003e Approaching\/exceeding maximum output capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWide input voltage range (85-264 VAC \/ 100-300 VDC)\u003c\/li\u003e\n\u003cli\u003eThree output voltages (+5.1V, +24V relay, +3.3V internal)\u003c\/li\u003e\n\u003cli\u003eComprehensive LED fault indication\u003c\/li\u003e\n\u003cli\u003eOver-temperature and overload protection\u003c\/li\u003e\n\u003cli\u003eSimple 2-slot installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRX3i system power supply\u003c\/li\u003e\n\u003cli\u003eNon-redundant automation systems\u003c\/li\u003e\n\u003cli\u003eApplications requiring wide input voltage range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use two IC695PSA040 modules for redundancy?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003eNo.\u003c\/strong\u003e The IC695PSA040 does not support redundancy. For redundant power, use \u003cstrong\u003eIC695PSD040\u003c\/strong\u003e or \u003cstrong\u003eIC695PSD140\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many slots does the PSA040 occupy?\u003c\/strong\u003e\u003cbr\u003eA: The IC695PSA040 occupies \u003cstrong\u003e2 slots\u003c\/strong\u003e in the RX3i universal backplane.\u003c\/p\u003e\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFor redundancy, use \u003cstrong\u003eIC695PSD040\u003c\/strong\u003e (10A) or \u003cstrong\u003eIC695PSD140\u003c\/strong\u003e (40W multi-output).\u003c\/li\u003e\n\u003cli\u003eVerify total system power consumption before selecting power supply.\u003c\/li\u003e\n\u003cli\u003eUse 14-22 AWG wire for proper terminal connection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53833800286392,"sku":"IC695PSA040","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC695PSA040_1_r180.png?v=1785480331","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-ic695psa040-rx3i-40-watt-power-supply-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}