{"product_id":"ge-fanuc-ic695psa140-power-supply-modules-pacsystems-rx3i","title":"GE Fanuc IC695PSA140 Power Supply Modules PACSystems RX3i","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eConfigured for multi-rail voltage regulation in RX3i PACSystems architectures, the \u003cstrong\u003eGE Fanuc IC695CHS007\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC695PSA140\u003c\/strong\u003e Power Supply Module, provides direct physical\/electrical execution. The component processes input source voltage to feed internal backplane rails, maintaining logical continuity across adjacent processor and input\/output modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695PSA140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e140 mm x 135 mm x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0-60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e40 W internal output capacity max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85-264 VAC \/ 100-300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs Supplied\u003c\/td\u003e\n\u003ctd\u003e5.1 VDC, 3.3 VDC, and 24 VDC rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Ratings\u003c\/td\u003e\n\u003ctd\u003e5.1 VDC at 6 A \/ 3.3 VDC at 9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Redundancy Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module maps power health statistics directly onto the RX3i backplane bus layer, validating system infrastructure health in real time. It supports load-sharing configurations when integrated with parallel power components on the same rack, establishing firmware flash compatibility across standard execution cycles. This power delivery management enables predictable data throughput over Profinet and EtherNet\/IP deterministic networks without risk of voltage dropouts during peak I\/O density scaling spikes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this power supply module support hot-swap replacement within an active rack?\u003c\/p\u003e\n\u003cp\u003eA: No. Complete input power isolation is required before extracting or inserting the module. Removing the primary power source hardware while the backplane is energized can induce severe transient arc voltage faults, causing diagnostic software halts or physical component degradation across adjacent processing units.\u003c\/p\u003e\n\u003cp\u003eQ: How is the load-sharing mechanism configured between dual power units?\u003c\/p\u003e\n\u003cp\u003eA: Load sharing executes automatically when two identical modules occupy the same backplane framework. The hardware internally matches output impedance parameters, allowing balanced current distribution across the 5.1 VDC and 3.3 VDC rails to protect against single-point supply failures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module exclusively in dedicated power slots on the far left of the rack assembly to optimize backplane voltage distribution.\u003c\/li\u003e\n\u003cli\u003eTerminate incoming AC or DC field supply lines using copper conductors rated for a minimum of 75 deg C, securing the terminal blocks to the specified torque limit.\u003c\/li\u003e\n\u003cli\u003eConnect a low-impedance external copper strap from the frame ground terminal directly to the central enclosure ground bus to dissipate high-frequency electrical noise.\u003c\/li\u003e\n\u003cli\u003eMaintain clear vertical spacing of 100 mm above and below the chassis to prevent thermal entrapment and ensure continuous passive cooling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53523823263928,"sku":"IC695PSA140","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC695PSA140_2.jpg?v=1780043562","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-ic695psa140-power-supply-modules-pacsystems-rx3i","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}