{"product_id":"ge-fanuc-pacsystems-rx3i-analog-input-module-ic694alg220","title":"GE Fanuc PACSystems RX3i Analog Input Module IC694ALG220","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eConfigured for precise voltage signal acquisition in PACSystems RX3i networks, the \u003cstrong\u003eGE Fanuc IC694ALG220\u003c\/strong\u003e (\u003cstrong\u003eIC694ALG220\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. This hardware component accepts 4 unipolar analog input channels to interface directly with field transmitters generating continuous voltage potentials. The module converts these incoming physical signals into discrete 12-bit binary values mapped across internal system registers.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694ALG220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc (PACSystems RX3i)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.2 cm x 14.1 cm x 11.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e27 mA at 5 VDC from backplane, 98 mA at 24 VDC from backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e4 single-ended, unipolar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e0 to 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e5 ms per selected channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit binary precision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling and Backplane Bus Communications\u003c\/h3\u003e\n\u003cp\u003eThe hardware form factor matches standard single-slot dimensions, facilitating efficient I\/O density scaling inside standard RX3i backplane rack structures. Module parameters and conversion updates are processed in strict synchronization with the CPU execution cycle via configured backplane bus communication velocity frameworks. The internal diagnostic subsystem evaluates voltage scaling boundaries, confirming that data pathways remain consistent with system-wide firmware flash compatibility tables.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module require an external 24 VDC loop power supply for input channel operation?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal logic and the signal conditioning networks derive all required operational current straight from the 5 VDC and 24 VDC power rails of the RX3i chassis backplane.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module react if an input signal voltage exceeds the maximum 10 VDC boundary limit?\u003c\/p\u003e\n\u003cp\u003eA: The internal converter registers will latch at the maximum count value ($4095$ in decimal). Prolonged overvoltage spikes up to a continuous 30 VDC will not damage the module circuits, but values above this limit breach structural isolation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Framework\u003c\/strong\u003e: Connect all signal wires using twisted-pair cables with overall foil shielding. Terminate the drain wire element at a clean single-point panel ground bus inside the enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Attachment Procedure\u003c\/strong\u003e: Insert the module into the targeted slot by aligning the upper and lower guide rails. Pivot the assembly firmly into the backplane until the faceplate latch engages securely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cable Isolation\u003c\/strong\u003e: Maintain physical isolation distances between low-voltage analog input conductors and high-power AC motor starters or inductive power circuits to minimize signal distortion.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53512505032888,"sku":"IC694ALG220","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC694ALG220_1.jpg?v=1779789554","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-pacsystems-rx3i-analog-input-module-ic694alg220","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}