{"product_id":"ge-fanuc-series-90-30-ic693mdl733-12-24vdc-0-5a-positive-logic-8-point-output-module","title":"GE Fanuc Series 90-30 IC693MDL733 12\/24VDC 0.5A Positive Logic 8-Point Output Module","description":"\u003ch2\u003e\u003cstrong\u003eModule Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693MDL733\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability discrete output module specifically designed for the GE Fanuc Series 90-30 PLC family. It features eight independent output points grouped into a single bank, utilizing positive logic (sourcing) circuitry. This module is the standard choice for interfacing with mid-range DC field devices such as indicator lights, small relays, and low-power interposing circuits where a 0.5A current capacity is required per channel.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693MDL733\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates by sourcing current from the user-supplied power terminal to the connected load. It is designed to withstand the rugged environments typical of industrial control cabinets while maintaining precise switching timing.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete Positive Logic (Sourcing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 (One group of 8)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 \/ 24 Volts DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 to 24 VDC (+20%, -15%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Amperes maximum per point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Load Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 Amperes total per module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 mA (from the +5V DC PLC bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 Volts (field-to-logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time (On\/Off)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 milliseconds maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage Drop\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2 VDC maximum in ON state\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal fusing for short-circuit safety\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cstrong\u003eApplication and Integration Notes\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eEngineers selecting the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693MDL733\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eshould ensure that the cumulative load for all eight points does not exceed the 2.0A module limit, especially in high-temperature environments. While each point can handle 0.5A individually, concurrent activation of all points requires thermal management. This module is frequently used in legacy migration projects where Series 90-30 hardware must remain operational under the Emerson automation umbrella.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFunctional Comparison: IC693MDL733 vs. IC693MDL732\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eWhile both modules serve as DC output components for the Series 90-30, they cater to different electrical requirements:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIC693MDL733\u003c\/strong\u003e: Positive Logic (Sourcing). Current flows from the module to the load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIC693MDL732\u003c\/strong\u003e: Negative Logic (Sinking). The load is connected to the positive supply, and the module completes the path to ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eEngineering FAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a field-side short circuit occurs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693MDL733\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis equipped with internal fuses to prevent damage to the backplane and neighboring modules. If a fault occurs, the fuse will interrupt the circuit, necessitating a diagnostic check of the field wiring before replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the logic side is powered by the PLC backplane (50 mA draw), the field-side devices require an external 12\/24 VDC power supply connected to the module’s terminal block.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53075078807736,"sku":"IC693MDL733","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC693MDL733.jpg?v=1773970787","url":"https:\/\/www.globalpetroparts.com\/products\/ge-fanuc-series-90-30-ic693mdl733-12-24vdc-0-5a-positive-logic-8-point-output-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}