{"product_id":"ge-is200vrtdh1d-mark-vi-rtd-input-board","title":"GE | IS200VRTDH1D | Mark VI RTD Input Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS200VRTDH1D (IS200VRTDH1D) functions as a dedicated Resistance Temperature Detector (RTD) input board within the Speedtronic Mark VI gas and steam turbine control framework. This 100% brand new, authentic factory-sealed component accepts direct temperature signals from field-mounted RTD sensors embedded deep within critical mechanical systems. Industrial operators deploy this board in thermal power stations, petrochemical facilities, and heavy manufacturing plants to monitor bearing temperatures, exhaust gas profiles, and generator stator windings. By translating raw resistance changes into precise, digitized temperature values, the board provides the core control system with real-time process visibility. This fast, deterministic feedback loop enables immediate thermal protection execution, prevents mechanical breakdown from overheating, and eliminates costly unplanned turbine shutdowns.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe alpha-numeric structure of the IS200VRTDH1D model number indicates the hardware assembly architecture developed by General Electric:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIS200:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates the standard printed circuit board (PCB) assembly platform within the Mark VI system line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVRTD:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEstablishes the functional acronym for the VME-based Resistance Temperature Detector input module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eH1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifies the group one configuration category, dictating the baseline channel density and component layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eD:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates the latest functional hardware revision layer certified by the factory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS200VRTDH1D\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VI Speedtronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTD Input Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 discrete RTD input channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported RTD Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Ohm Copper, 100 Ohm Platinum, 120 Ohm Nickel, 200 Ohm Platinum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Conversion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDedicated 16-bit analog-to-digital converters per group\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 Hz nominal frame rate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0-60 Celsius (32-140 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40-85 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-95 percent non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard VME card dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe IS200VRTDH1D provides robust structural and electrical solutions to solve common temperature logging challenges in harsh environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Noise Suppression and Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-frequency electrical noise from generator fields often corrupts low-voltage RTD signals. This board features onboard differential filtering networks and galvanic isolation barriers. These components eliminate common-mode noise and prevent ground-loop cross-talk, preserving measurement accuracy over extended field cable runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOpen\/Short Circuit Detection Loop:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal diagnostics continuously check sensor line health. If a field wire breaks or shorts out, the board flags the precise channel instantly and logs a diagnostic alarm to the CPU. This prevents the control system from misinterpreting a broken wire as an over-temperature trip, avoiding false turbine shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDynamic Lead Wire Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board utilizes a three-wire configuration tracking architecture to calculate lead-wire resistance dynamically. It automatically subtracts cable resistance from the sensor reading, ensuring highly accurate temperature data even when the physical RTD sits hundreds of meters away from the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this IS200VRTDH1D board arrive with original packaging and documentation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply this component in 100% brand new, original factory-sealed condition, complete with original box protection and factory serial labels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IS200VRTDH1D replace an older revision like the H1A or H1B?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"D\" suffix indicates the latest factory update, which generally offers backwards compatibility with earlier revisions like the H1A, H1B, or H1C within the same group block. However, you should check your Mark VI system configuration files and toolbox software version to ensure seamless hardware registration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of RTD sensors can I connect to this board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe board natively supports standard industrial 3-wire RTDs, including 100 Ohm Platinum (Pt100), 10 Ohm Copper, 120 Ohm Nickel, and 200 Ohm Platinum sensors. You can configure each channel independently via the system software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53491715440824,"sku":"IS200VRTDH1D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IS200VRTDH1D_3_1.jpg?v=1779351456","url":"https:\/\/www.globalpetroparts.com\/products\/ge-is200vrtdh1d-mark-vi-rtd-input-board","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}