{"product_id":"ge-is220ydias1ak-mark-vie-discrete-input-i-o-pack-module","title":"GE | IS220YDIAS1AK Mark VIe Discrete Input I\/O Pack Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS220YDIAS1AK functions as a high-density discrete input I\/O pack within the General Electric Mark VIe Speedtronic turbine control framework. This intelligent, processor-backed module plugs directly onto compatible discrete input terminal boards to interface field-side dry contacts, limit switches, pressure switches, and sequence-of-events (SOE) sensor loops with the central controller network. It converts raw electrical state changes from the field into digitized logic states, transmits this tracking data over redundant industrial Ethernet IONet ports, and records millisecond-level timestamps for diagnostic event profiling.\u003c\/p\u003e\n\u003cp\u003eWe supply this technical automation component exclusively as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed stock\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto guarantee clean electronic internal pathways and flawless structural execution inside your control panels.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IS220YDIAS1AK encloses localized microcontrollers, dual RJ-45 transceiver nodes, and a high-density 37-pin mating socket within a ruggedized protective housing. The table below outlines the core electrical, network, and environmental specifications:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS220YDIAS1AK\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VIe Speedtronic System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Group\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYDIA (Discrete Input Input\/Output Pack Assembly)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Revision\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS1AK (Designates specific component baseline with enhanced filtering)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual 10\/100 Base-TX RJ-45 copper Ethernet ports for IONet redundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProcesses up to 24 or 48 dry contact inputs (depending on terminal board)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSequence of Events (SOE)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCaptures contact transitions with 1-millisecond resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Supply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.0 V DC nominal (Accepts 18.5 V DC to 32.0 V DC input range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMating Connector\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x 37-pin D-sub plug matching standard TIDI\/TADI terminal boards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% relative humidity, non-condensing operating boundary\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Sequence of Events (SOE) Tracking:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnboard timers timestamp discrete input state changes at a 1-millisecond resolution. This precise internal tracking allows plant operators to analyze cascade trips instantly, isolating the exact primary device that initiated a turbine shutdown sequence.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Dual-Port IONet Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes two fully independent RJ-45 Ethernet ports to broadcast signal data simultaneously across parallel IONet loops. If an external network switch or link drops unexpectedly, the secondary network path maintains data throughput with zero signal loss or latency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Contact Chatter Filtering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital hardware filters on the board suppress electrical contact bounce and line ringing caused by aging field mechanical switches. This clearing mechanism prevents false alarm triggers and processing overhead within the master control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Terminal Standoff Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe structural casing includes built-in securing bolts that thread directly into terminal board standoffs. This rigid mechanical layout eliminates loose component vibration, guarantees perfect alignment for the 37-pin interface pins, and removes the need for custom backplate bracket drilling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What differentiates the 'S1AK' version of this discrete input pack from the older 'S1A' baseline?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The \"S1AK\" revision introduces an updated internal electronic layout featuring enhanced electromagnetic shielding and improved thermal dissipation management. It provides a more robust performance envelope in high-ambient-noise switchgear rooms while retaining full backward physical and software compatibility with standard TIDI terminal structures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I hot-swap the IS220YDIAS1AK module while the turbine control system is active?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes. In dual or Triple Modular Redundant (TMR) terminal board configurations, you can unbolt and replace a faulted IS220YDIAS1AK pack while live. The parallel packs on the terminal board maintain signal sensing during the replacement window, preventing process downtime or false trip signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How does the module handle excitation voltage monitoring for the field contacts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: The IS220YDIAS1AK monitors the field excitation voltage loops directly through its interface pins. If the terminal board excitation voltage drops below the operating threshold or an open-circuit path occurs, the pack registers a localized diagnostics fault and transmits an alarm to the ControlST platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53477541511352,"sku":"IS220YDIAS1AK","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IS220YDIAS1AK_2_1.jpg?v=1779087922","url":"https:\/\/www.globalpetroparts.com\/products\/ge-is220ydias1ak-mark-vie-discrete-input-i-o-pack-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}