{"product_id":"ge-mark-v-drive-control-and-lan-communications-board-ds200ldccg1aaa","title":"GE Mark V Drive Control and LAN Communications Board DS200LDCCG1AAA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE DS200LDCCG1AAA (DS200LDCCG1A)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary intelligence hub and communication gateway for the GE Mark V Drive and Turbine Control system. This Drive Control and LAN Communications (LDCC) board integrates high-speed computational power with robust network interfacing, managing everything from core drive logic to ARCNET and DLAN communications. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your critical power generation or industrial drive systems operate with maximum deterministic accuracy. The DS200LDCCG1AAA effectively centralizes operator interface data and coordinates real-time control signals across the entire Mark V rack.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDS200LDCCG1AAA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDrive Control and LAN Communications (LDCC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMicroprocessors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-processor architecture (including 80196 and TMS320 processors)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eARCNET, DLAN (Drive LAN), RS-232 Serial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOn-board 14-segment alphanumeric LED display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple high-density ribbon headers (J-ports)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C (32 to 131 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe DS200LDCCG1AAA offers distinct technical solutions for complex automation challenges:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAsynchronous Processing Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board utilizes multiple dedicated microprocessors to separate communication tasks from real-time control logic. This prevents network congestion from lagging the critical speed or torque control loops, maintaining system stability during high data traffic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE engineered the \"G1AAA\" revision with high-tolerance industrial components that resist the performance drift caused by heat-intensive turbine cabinet environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect-Link Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated 14-segment LED display provides immediate, on-site hardware health status. Engineers can verify the boot sequence and isolate network failures without needing an external PC, significantly reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Fidelity Signal Paths:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecialized shielding and multi-layer PCB routing minimize electromagnetic interference (EMI) on the internal communication bus, ensuring error-free data transmission between the LDCC and the Signal Processor boards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Site Configuration Protocols\u003c\/h3\u003e\n\u003cp\u003eTo ensure the performance of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware, engineers must adhere to the following protocols:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEPROM Migration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe DS200LDCCG1AAA features several socketed EEPROM\/EPROM chips containing your site-specific application software. You must move these chips from your original board to the new unit. Observe the notch orientation carefully to avoid permanent chip damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJumper Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis board contains numerous hardware jumpers that define signal scaling and communication ID settings. You must match the jumper positions on the new board exactly to those on the replaced unit before applying power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatic Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-density CMOS processors on the LDCC are highly susceptible to ESD. Use a grounded wrist strap and anti-static handling procedures throughout the installation process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DS200LDCCG1AAA replace an older DS200LDCCG1A model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \"AAA\" suffix denotes the specific revision level. It maintains full backward compatibility with earlier G1 series boards and functions as a direct drop-in replacement while utilizing modernized component standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the board ship with pre-loaded drive parameters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe board hardware is brand new and blank. It requires your specific site firmware, which is stored in the socketed chips. Transferring your original chips to this new board ensures the drive retains its unique configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I check if the LED display shows a communication error?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst, verify the seating of the ARCNET ribbon cables and the orientation of the communication-related EPROMs. If the jumpers for the LAN ID are set incorrectly, the board will fail to sync with the rest of the Mark V system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53452595855544,"sku":"DS200LDCCG1AAA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/DS200LDCCG1AAA_2_e93f2b74-fcef-49b5-b322-87d11e25e982.jpg?v=1778464515","url":"https:\/\/www.globalpetroparts.com\/products\/ge-mark-v-drive-control-and-lan-communications-board-ds200ldccg1aaa","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}