{"product_id":"ge-mark-vi-terminal-contact-board-is200tbcih1b","title":"GE Mark VI Terminal Contact Board  IS200TBCIH1B","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS200TBCIH1B (IS200TBCIH1B) operates as a heavy-duty Contact Terminal Board within the Speedtronic Mark VI turbine control framework. This 100% brand new, authentic factory-packaged board provides the primary physical interface for field wiring, routing discrete inputs and dry contact signals directly to the control rack. Infrastructure facilities deploy this termination block inside power generation plants, chemical refineries, and heavy industrial mills to centralize complex wire networks. The robust physical circuit paths handle high-voltage excitation signals and deliver clean electrical isolation between the external plant environment and sensitive control processors. By stabilizing terminal junctions and providing direct diagnostic access loops, this board simplifies field commissioning, stops loose-wire noise anomalies, and secures system runtime to mitigate costly unprogrammed process shutdowns.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe structural alpha-numeric designations within the IS200TBCIH1B model number detail specific hardware traits and design iterations specified by General Electric:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIS200:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesignates the standard printed circuit board (PCB) base construction profile within the Mark VI product group.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTBCI:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdentifies the functional acronym representing the Terminal Block Contact Input board configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eH1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClassifies the specific assembly block variation, specifying the number of physical terminal screws and connector headers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eB:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHighlights the certified factory revision layer, denoting component-level hardware refinements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS200TBCIH1B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VI Speedtronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Contact Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo rows of high-density barrier terminal blocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccepts 12 to 24 AWG solid or stranded field wires\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 24 discrete contact input channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOnboard Connectors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-pin D-shell cable plug interfaces for I\/O pack links\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30-65 deg Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40-85 deg Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-95 percent non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe physical build and design choices of the IS200TBCIH1B systematically solve terminal wiring and interference pain points common to harsh turbine environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Barrier Screwed Terminals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial enclosures often experience intense vibration profiles from adjacent gas turbines or compressors. This board features rugged, high-barrier screw terminal strips that clamp conductors tightly. This design completely eliminates mechanical wire backing-out issues and maintains steady gas-tight connections over years of continuous operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Surge and Noise Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLong field cable runs from remote limit switches collect electromagnetic interference (EMI) and lightning transients. The board integrates localized metal oxide varistors (MOVs) and high-frequency RC filtering networks on every input line. These components absorb high-energy voltage spikes and suppress cross-talk noise before it can corrupt downstream digital logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Diagnostic Test Points:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo speed up troubleshooting sequences, the board layout provides dedicated, exposed voltage test points adjacent to each input channel. Technicians verify loop voltage metrics or inject simulation signals safely without stripping field insulation or disturbing active factory wires, cutting down loop-checking times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IS200TBCIH1B board include the factory-installed terminal screws?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. This module arrives in 100% brand new, original factory-sealed condition with all terminal block assemblies, terminal screws, and multi-pin D-sub connectors pre-soldered and fully tested by General Electric.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the IS200TBCIH1B with standard Mark VIe distributed I\/O packs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile this board originated within the standard Mark VI cabinet architecture, certain migration setups and terminal board layouts allow cross-linking with specific Mark VIe packs. You must check your system's engineering control drawing sheets to verify exact cable and signaling compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the recommended torque specification for the field wiring screws?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo ensure proper electrical contact and prevent thread damage, tighten the barrier terminal block screws using a calibrated screwdriver to a torque range of 0.56-0.79 Nm (5-7 in-lbs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53491763708088,"sku":"IS200TBCIH1B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/aeaf95e4633491bd110513637e483865_medium_1.jpg?v=1779352084","url":"https:\/\/www.globalpetroparts.com\/products\/ge-mark-vi-terminal-contact-board-is200tbcih1b","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}