{"product_id":"ge-multilin-ur6hh-ur-6hh-direct-i-o-module","title":"GE Multilin UR6HH UR 6HH Direct I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-6HH\u003c\/strong\u003e is a \u003cstrong\u003eDigital I\/O Module\u003c\/strong\u003e from \u003cstrong\u003eGE Multilin\u003c\/strong\u003e, designed for the \u003cstrong\u003eUR Series Universal Relay\u003c\/strong\u003e platform. This module provides \u003cstrong\u003e6 Form-A outputs\u003c\/strong\u003e (no monitoring) and \u003cstrong\u003e4 digital contact inputs\u003c\/strong\u003e, enabling the relay to connect to various devices in the operating system such as selector switches, pushbuttons, limit switches, fans, lights, and valves.\u003c\/p\u003e\n\n\u003cp\u003eThe UR-6HH supports both \u003cstrong\u003ewet and dry contact\u003c\/strong\u003e types. Dry contacts provide isolation between devices, while wet contacts do not. The module is fully compatible with \u003cstrong\u003eEnerVista UR\u003c\/strong\u003e software for streamlined configuration and diagnostics.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e6 × Form-A outputs\u003c\/strong\u003e (normally open, no monitoring) for direct control applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e4 × Digital contact inputs\u003c\/strong\u003e for external signal monitoring\u003c\/li\u003e\n  \u003cli\u003eSupports both \u003cstrong\u003ewet and dry contact\u003c\/strong\u003e types\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular plug-and-play design\u003c\/strong\u003e for easy installation and upgrades\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexLogic™ programmable logic\u003c\/strong\u003e support for custom protection schemes\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eCompatible with EnerVista UR Setup Software\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGeneral Electric (GE) Multilin\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eProduct Family\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series Universal Relay\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital I\/O Module (Order Code: 6H)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital Inputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e4 contact inputs\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eDigital Outputs\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\n\u003cstrong\u003e6 × Form-A\u003c\/strong\u003e (NO, no monitoring)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eContact Types\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWet or Dry contacts supported\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eMounting\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUR Series chassis slot\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eConfiguration Software\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eApprox. \u003cstrong\u003e1.15 kg\u003c\/strong\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCountry of Origin\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eUSA \/ Canada\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial automation\u003c\/strong\u003e — process control systems and building management\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower generation\u003c\/strong\u003e — monitoring and control of auxiliary equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOil and gas\u003c\/strong\u003e — data acquisition and equipment control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater and wastewater\u003c\/strong\u003e — pump and valve control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubstation automation\u003c\/strong\u003e — status monitoring and interlocking logic\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThe UR-6HH is fully compatible with the \u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e universal relay family. Modules can be mixed within the same chassis for scalable system upgrades. Always ensure replacement modules match the \u003cstrong\u003eoriginal type and order code\u003c\/strong\u003e to prevent hardware mismatch errors.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Completely de-energize the UR relay chassis. \u003cstrong\u003eNever install or remove modules while energized.\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Verification:\u003c\/strong\u003e Confirm the target slot is empty and matches the module orientation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Slide the UR-6HH into the chassis guide rails, aligning the rear terminal block with the backplane connector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Tighten the faceplate retention screws to the specified torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect field wiring per the UR series wiring diagram. Observe correct polarity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Power on and configure via \u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e software.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \"6H\" order code signify?\u003c\/strong\u003e\u003cbr\u003e\nA: In the UR series order code structure, \"6H\" designates this specific digital I\/O module configuration: \u003cstrong\u003e6 Form-A outputs + 4 digital inputs\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between wet and dry contacts?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eDry contacts\u003c\/strong\u003e are passive contacts that provide isolation between devices. \u003cstrong\u003eWet contacts\u003c\/strong\u003e are active contacts that do not provide the same isolation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use UR-6HH for breaker tripping?\u003c\/strong\u003e\u003cbr\u003e\nA: The Form-A outputs can be used for control applications. For high-current tripping, verify contact ratings or consider trip-rated modules.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swapping supported?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003eNo.\u003c\/strong\u003e Always remove control power before installing or removing any module.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChoose UR-6HH\u003c\/strong\u003e when you need \u003cstrong\u003e6 Form-A outputs with 4 inputs\u003c\/strong\u003e for general-purpose control.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eForm-A outputs with current monitoring\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-6NH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFor \u003cstrong\u003eall Form-C outputs\u003c\/strong\u003e, consider the \u003cstrong\u003eUR-6CH\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eAlways cross-reference the \u003cstrong\u003eUR series order code guide\u003c\/strong\u003e before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:15px 0;\"\u003e\n  \u003ctr style=\"background:#f5f5f5;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eUR-6HH \/ UR6HH\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eGE Multilin UR Series Digital I\/O Module — 6 Form-A Outputs + 4 Contact Inputs\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53759514706104,"sku":"UR6EV","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/UR6HH.png?v=1783925622","url":"https:\/\/www.globalpetroparts.com\/products\/ge-multilin-ur6hh-ur-6hh-direct-i-o-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}