{"product_id":"general-electric-ic695hsc308-8-channel-high-speed-counter-module","title":"General Electric IC695HSC308 8-Channel High-Speed Counter Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IC695HSC308\u003c\/strong\u003e is an \u003cstrong\u003e8-Channel High-Speed Counter Module\u003c\/strong\u003e for the Emerson PACSystems RX3i programmable automation controller platform. It processes rapid pulse signals up to \u003cstrong\u003e1.5 MHz\u003c\/strong\u003e for industrial applications including velocity measurement, motion control, turbine flow metering, and material handling.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e IC695HSC308\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PACSystems RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e High-Speed Counter Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCounter Channels:\u003c\/strong\u003e \u003cstrong\u003e8 independent counters\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Inputs:\u003c\/strong\u003e \u003cstrong\u003e16 configurable inputs\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Outputs:\u003c\/strong\u003e \u003cstrong\u003e14 configurable outputs\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCounter Types:\u003c\/strong\u003e A, B, C, D, E, Z, and user-defined\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Count Rate:\u003c\/strong\u003e \u003cstrong\u003e1.5 MHz\u003c\/strong\u003e (A-Quad B mode); \u003cstrong\u003e750 kHz\u003c\/strong\u003e (Type C\/user-defined with 4 outputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCount Range:\u003c\/strong\u003e \u003cstrong\u003e-2,147,483,648 to +2,147,483,647\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Filtering:\u003c\/strong\u003e Configurable with \u003cstrong\u003e40 MHz\u003c\/strong\u003e internal oversampling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOscillator Accuracy:\u003c\/strong\u003e ±100 ppm over temperature range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOscillator Drift:\u003c\/strong\u003e ±5 ppm\/year\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse Capture Response Time:\u003c\/strong\u003e ≤ \u003cstrong\u003e2 µs\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e \u003cstrong\u003e5 VDC\u003c\/strong\u003e (4.7–5.5 V) or \u003cstrong\u003e12–24 VDC\u003c\/strong\u003e (10–26.4 V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Input Voltage:\u003c\/strong\u003e 35 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 10 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e 4.7–40 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e \u003cstrong\u003e1.5 A\u003c\/strong\u003e max per channel; \u003cstrong\u003e10.5 A\u003c\/strong\u003e max per module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Current:\u003c\/strong\u003e 4.5 A \u0026lt;450 µs (self-protected)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage Drop:\u003c\/strong\u003e 0.35 V @ 1.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Delay (Off→On):\u003c\/strong\u003e \u003cstrong\u003e125 µs\u003c\/strong\u003e @ 1.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Delay (On→Off):\u003c\/strong\u003e \u003cstrong\u003e85 µs\u003c\/strong\u003e @ 1.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power:\u003c\/strong\u003e 94 mA @ 5V; 561 mA @ 3.3V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 250 VAC continuous; 2500 VAC\/1 min (field to backplane)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cstrong\u003e0°C to 60°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 118 × 72 × 35 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e \u003cstrong\u003e0.4 kg\u003c\/strong\u003e (2720g shipping weight per supplier)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e \u003cstrong\u003eCE, UL\/cUL 508, 1604, ATEX\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCore Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8 independent counter channels with configurable types (A-Z, user-defined)\u003c\/li\u003e\n\u003cli\u003eUltra-high 1.5 MHz count rate for precision motion applications\u003c\/li\u003e\n\u003cli\u003e16 high-speed inputs with 40 MHz oversampling filter\u003c\/li\u003e\n\u003cli\u003e14 high-speed outputs with 1.5A per channel capacity\u003c\/li\u003e\n\u003cli\u003eSelf-healing overcurrent\/thermal protection on outputs\u003c\/li\u003e\n\u003cli\u003eHot insertion\/extraction capability for online maintenance\u003c\/li\u003e\n\u003cli\u003eModule fault reporting and I\/O interrupt support\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMotion control and servo positioning\u003c\/li\u003e\n\u003cli\u003eTurbine flow metering and RPM measurement\u003c\/li\u003e\n\u003cli\u003eMaterial handling conveyor counting\u003c\/li\u003e\n\u003cli\u003eHigh-speed packaging line control\u003c\/li\u003e\n\u003cli\u003eEncoder feedback processing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum count frequency?\u003c\/strong\u003e\u003cbr\u003e\nA: \u003cstrong\u003e1.5 MHz\u003c\/strong\u003e in A-Quad B mode. For Type C with 4 outputs, the maximum is \u003cstrong\u003e750 kHz\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the module be hot-swapped?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, the IC695HSC308 supports \u003cstrong\u003ehot insertion\/extraction\u003c\/strong\u003e for online maintenance without system shutdown.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the RX3i rack (or use hot-swap in non-hazardous zones).\u003c\/li\u003e\n\u003cli\u003eInsert the IC695HSC308 into any slot of the RX3i universal backplane.\u003c\/li\u003e\n\u003cli\u003eConnect encoder or pulse generator signals to the high-speed inputs.\u003c\/li\u003e\n\u003cli\u003eConfigure counter types and filter settings via RX3i programming software.\u003c\/li\u003e\n\u003cli\u003eVerify count accuracy using known pulse frequencies.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify encoder output type (5V vs. 12-24V) matches input configuration.\u003c\/li\u003e\n\u003cli\u003eFor lower-speed counting, consider standard digital input modules.\u003c\/li\u003e\n\u003cli\u003eEnsure total output current (10.5A max) is not exceeded.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for high-frequency pulse signals to minimize noise.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53833668395192,"sku":"IC695HSC308","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IC695HSC308_2_5e916214-46ed-4a55-b79b-a56bb481e0b0.png?v=1785480342","url":"https:\/\/www.globalpetroparts.com\/products\/general-electric-ic695hsc308-8-channel-high-speed-counter-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}