{"product_id":"general-electric-is200tturh1c-terminal-turbine-board","title":"General Electric IS200TTURH1C Terminal Turbine Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200TTURH1C\u003c\/strong\u003e is a \u003cstrong\u003eTurbine Control Terminal Board\u003c\/strong\u003e for the Mark VI and Mark VIe Speedtronic systems. It provides \u003cstrong\u003egenerator synchronization and trip logic interfacing\u003c\/strong\u003e through hardware mechanisms and interconnections, featuring three onboard relays, six 37-pin interfaces, and two centrally positioned transformers. The board supports configurable simplex or TMR voting via jumper switches, making it adaptable to both standard and redundant turbine control architectures. \u003cstrong\u003eNote:\u003c\/strong\u003e This is a synchronization\/trip terminal board, not a primary speed control module.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e IS200TTURH1C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Turbine Control Terminal Board (Synchronization \u0026amp; Trip Logic)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark VI \/ Mark VIe Speedtronic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelays:\u003c\/strong\u003e 3 onboard surface-mounted relays\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterfaces:\u003c\/strong\u003e Six 37-pin D-shell connectors (male\/female)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTransformers:\u003c\/strong\u003e 2 centrally positioned transformers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoting Configuration:\u003c\/strong\u003e Simplex or TMR (jumper-selectable)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVariable Resistors:\u003c\/strong\u003e Onboard for signal adjustment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated Speed:\u003c\/strong\u003e 5100 RPM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 125 VDC (typical)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e ~35 × 25 × 6 cm (varies by source)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.5–0.8 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30°C to +65°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eMount the IS200TTURH1C in a standard Mark VI\/VIe rack.\u003c\/li\u003e\n  \u003cli\u003eSet jumper switches for simplex or TMR voting according to system architecture.\u003c\/li\u003e\n  \u003cli\u003eConnect 37-pin cables to PTUR and VTUR boards for turbine control interconnection.\u003c\/li\u003e\n  \u003cli\u003eVerify relay operation and transformer continuity using diagnostic tools.\u003c\/li\u003e\n  \u003cli\u003ePerform synchronization tests to confirm proper generator paralleling functionality.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: What does TTUR stand for?\u003c\/strong\u003e\u003cbr\u003eA: TTUR is the functional acronym for Turbine Trip\/Control Terminal Board, handling synchronization and trip logic interfacing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: Is TTUR a speed control board?\u003c\/strong\u003e\u003cbr\u003eA: No. TTUR is a terminal board for synchronization and trip circuits. Primary turbine speed control is handled by dedicated processor boards such as the TMR controller.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: How is TMR voting configured?\u003c\/strong\u003e\u003cbr\u003eA: TMR voting is enabled via onboard jumper switches; consult the Mark VI installation manual for specific jumper positions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: What boards does TTUR interface with?\u003c\/strong\u003e\u003cbr\u003eA: It communicates with PTUR (Primary Turbine) and VTUR (Vibration\/Turbine) boards via D-shell connectors and terminal blocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUse IS200TTURH1C for generator synchronization and turbine trip interfacing in Mark VI\/VIe systems.\u003c\/li\u003e\n  \u003cli\u003eEnsure jumper settings match the redundancy architecture (simplex vs. TMR) before installation.\u003c\/li\u003e\n  \u003cli\u003ePair with compatible PTUR\/VTUR boards for complete turbine control functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eData Source:\u003c\/strong\u003e Parameters verified against WOC and Ubest PLC hardware specifications. For complete wiring and jumper configuration, refer to GE Mark VI terminal board installation manual (GEI-100462 series).\u003c\/em\u003e\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53776596467896,"sku":"IS200TTURH1C","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IS200TTURH1C_2r180_9a23305f-19aa-4495-acc6-6b04a0c37c61.png?v=1784184283","url":"https:\/\/www.globalpetroparts.com\/products\/general-electric-is200tturh1c-terminal-turbine-board","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}