{"product_id":"general-electric-is230jpdgh1b-dc-power-distribution-module","title":"General Electric IS230JPDGH1B DC Power Distribution Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS230JPDGH1B\u003c\/strong\u003e is a \u003cstrong\u003e28 VDC Power Distribution DIN Rail Module\u003c\/strong\u003e for Mark VIe control systems. It provides stable, reliable DC power distribution to various electronic devices, including PLCs, inverters, sensors, and I\/O modules. Featuring dual power input support, over-current protection, and modular DIN rail mounting, it ensures high system redundancy and easy maintenance in industrial automation and power generation applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e IS230JPDGH1B\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e DC Power Distribution DIN Rail Module\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Mark VIe\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 28 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 28 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e Varies by configuration (supports multiple loads)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Standard DIN rail\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Inputs:\u003c\/strong\u003e Dual input support for redundancy\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Over-current protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Design:\u003c\/strong\u003e Hot-swappable, supports system expansion\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Standard DIN rail module size\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~0.5 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -20°C to +70°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eMount the IS230JPDGH1B on a standard 35 mm DIN rail in the control cabinet.\u003c\/li\u003e\n  \u003cli\u003eConnect primary and redundant 28 VDC power sources to the input terminals.\u003c\/li\u003e\n  \u003cli\u003eDistribute power to downstream modules (I\/O packs, sensors, actuators) via output terminals.\u003c\/li\u003e\n  \u003cli\u003eVerify over-current protection settings match connected load requirements.\u003c\/li\u003e\n  \u003cli\u003eMonitor power status via system diagnostics and check for fault indications.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: What is the advantage of dual power inputs?\u003c\/strong\u003e\u003cbr\u003eA: Dual inputs allow redundant power feeds; if one source fails, the other maintains power to critical loads without interruption.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: Can this module be hot-swapped?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the modular DIN rail design supports replacement without shutting down the entire system, provided proper bypass procedures are followed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: What protection does it offer?\u003c\/strong\u003e\u003cbr\u003eA: Built-in over-current protection prevents damage to downstream devices during short-circuit or overload conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSpecify IS230JPDGH1B for Mark VIe systems requiring organized 28 VDC power distribution.\u003c\/li\u003e\n  \u003cli\u003eCalculate total load current to ensure the module capacity is not exceeded.\u003c\/li\u003e\n  \u003cli\u003eDeploy dual-redundant power feeds for mission-critical I\/O and controller modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eData Source:\u003c\/strong\u003e Parameters based on WOC and distributor specifications. Detailed electrical ratings and wiring diagrams should be verified against GE Mark VIe power distribution documentation.\u003c\/em\u003e\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":53776598270136,"sku":"IS230JPDGH1B","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/IS230JPDGH1Br180.png?v=1784184269","url":"https:\/\/www.globalpetroparts.com\/products\/general-electric-is230jpdgh1b-dc-power-distribution-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}