{"product_id":"hima-f6217-analog-input-module-98-4621702","title":"HIMA F6217 Analog Input Module 98 4621702","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA F 6217\u003c\/strong\u003e is an \u003cstrong\u003e8-Channel Analog Input Module\u003c\/strong\u003e for safety-related industrial automation systems. It acquires current and voltage signals from field sensors with 12-bit resolution and SIL 3 certification for critical process monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e HIMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e F 6217\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 984621702\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e 8-Channel Analog Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal:\u003c\/strong\u003e 0\/4–20 mA current; 0–5\/10 V voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 0–5.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Input Voltage:\u003c\/strong\u003e 7.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current Range:\u003c\/strong\u003e 0–22 mA via shunt\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Input Current:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShunt Resistor:\u003c\/strong\u003e 250 Ω, 0.05%, 0.25 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Resistance:\u003c\/strong\u003e 100 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 12 bit (0 mV = 0, 5.5 V = 4095)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurand Update:\u003c\/strong\u003e 50 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Time:\u003c\/strong\u003e \u0026lt; 450 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Filter Time Constant:\u003c\/strong\u003e 10 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBasic Error:\u003c\/strong\u003e 0.1% at 25 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Error:\u003c\/strong\u003e 0.3% at 0–60 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Error Limit:\u003c\/strong\u003e 1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Strength:\u003c\/strong\u003e 200 V against GND\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Requirement:\u003c\/strong\u003e 4 TE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 5 VDC at 80 mA; 24 VDC at 50 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e −40 °C to +70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e −40 °C to +85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 168 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSafety Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIL:\u003c\/strong\u003e SIL 3 (IEC 61508, IEC 61511)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAK:\u003c\/strong\u003e AK6\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8-channel analog input for current and voltage sensors\u003c\/li\u003e\n\u003cli\u003e12-bit resolution with 0.1% basic accuracy\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between input channels and system ground\u003c\/li\u003e\n\u003cli\u003eBuilt-in input filter with 10 ms time constant\u003c\/li\u003e\n\u003cli\u003eRedundant measurement channels per input for safety integrity\u003c\/li\u003e\n\u003cli\u003eSelf-test on power-up and continuous diagnostic monitoring\u003c\/li\u003e\n\u003cli\u003eCompact 4 TE form factor for HIQuad and HIMax racks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What sensor types does F 6217 support?\u003c\/strong\u003e\u003cbr\u003eA: The module supports 2-wire and 4-wire transmitters with 0\/4–20 mA current output or 0–5\/10 V voltage output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the safety response time?\u003c\/strong\u003e\u003cbr\u003eA: The safety time is less than 450 ms from input fault detection to safe-state response.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require external shunt resistors?\u003c\/strong\u003e\u003cbr\u003eA: The module uses an internal 250 Ω shunt resistor for current measurement. No external shunt is required.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall the module into an available slot in the HIQuad or HIMax system rack.\u003c\/li\u003e\n\u003cli\u003eConnect field sensor wiring to the cable plug terminals.\u003c\/li\u003e\n\u003cli\u003eConfigure input type (current or voltage) and scaling via SILworX engineering tool.\u003c\/li\u003e\n\u003cli\u003eVerify channel diagnostics and safety time settings before commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelect F 6217 for 8-channel safety analog input in HIMA HIQuad or HIMax systems.\u003c\/li\u003e\n\u003cli\u003eVerify sensor output type (current vs. voltage) matches the configured input mode.\u003c\/li\u003e\n\u003cli\u003eFor applications requiring 16-bit resolution, verify alternative HIMA analog input modules.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":53862430507192,"sku":"F6217","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/F6217_2.png?v=1785480127","url":"https:\/\/www.globalpetroparts.com\/products\/hima-f6217-analog-input-module-98-4621702","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}