{"product_id":"honeywell-2mlp-acf2-free-voltage-ac-power-supply-module-85-264-vac-5-vdc-at-6-a","title":"Honeywell 2MLP-ACF2 Free-Voltage AC Power Supply Module, 85–264 VAC, 5 VDC at 6 A","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 2MLP-ACF2\u003c\/strong\u003e is a \u003cstrong\u003efree-voltage AC power supply module\u003c\/strong\u003e for the \u003cstrong\u003eMasterLogic-200 PLC system\u003c\/strong\u003e. It accepts a wide \u003cstrong\u003e85–264 VAC input range\u003c\/strong\u003e (rated 100–240 VAC) and delivers a regulated \u003cstrong\u003e5 VDC output at 6 A\u003c\/strong\u003e. With built-in \u003cstrong\u003eovercurrent protection\u003c\/strong\u003e, \u003cstrong\u003eovervoltage protection\u003c\/strong\u003e, \u003cstrong\u003eRUN relay output\u003c\/strong\u003e, and global voltage compatibility, this module provides reliable power delivery for industrial automation systems across diverse geographical installations.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e AC 85 V – 264 V (Rated: 100 V – 240 V)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Frequency:\u003c\/strong\u003e 47–63 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e DC 5 V (±2%)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 6.0 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e ≥ 60%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e ≤ 80 A peak\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection:\u003c\/strong\u003e ≥ 6.6 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection:\u003c\/strong\u003e 5.5 V – 6.5 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Fuse:\u003c\/strong\u003e Built-in, UL standard slow-blow (non-replaceable)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstantaneous Interruption Handling:\u003c\/strong\u003e ≤ 10 ms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRUN Relay Output:\u003c\/strong\u003e 24 VDC @ 0.5 A (Form-C contact)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelay Minimum Switching Load:\u003c\/strong\u003e 5 VDC @ 1 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResponse Time (On\/Off):\u003c\/strong\u003e ≤ 10 ms \/ ≤ 12 ms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelay Life Expectancy:\u003c\/strong\u003e Mechanical: 20M+ cycles; Electrical: 100K+ cycles\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED Status Indicator:\u003c\/strong\u003e ON when output voltage is normal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Specification:\u003c\/strong\u003e 0.75–2 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e RAV1.25-3.5, RAV2-3.5\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e 55 × 95 × 90 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.38 kg\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +55°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -25°C to +70°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% RH, non-condensing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e UL, CE\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Voltage Compatibility:\u003c\/strong\u003e 85–264 VAC input range eliminates the need for separate 110 V and 220 V power supply variants, simplifying global inventory and spare parts management.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Current Output:\u003c\/strong\u003e 6 A at 5 VDC supports fully loaded MasterLogic-200 chassis with multiple high-density I\/O and communication modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBuilt-In Protection Suite:\u003c\/strong\u003e Overcurrent (≥ 6.6 A), overvoltage (5.5–6.5 V), and slow-blow fuse protection safeguard the power supply and downstream modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRUN Relay Output:\u003c\/strong\u003e Form-C contact with 24 VDC @ 0.5 A rating enables external power-status monitoring and safety interlocking.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVisual Diagnostics:\u003c\/strong\u003e Front-panel LED provides immediate confirmation of normal output voltage, reducing troubleshooting time.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e 55 × 95 × 90 mm dimensions and 0.38 kg weight allow high-density mounting in space-constrained control panels.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 2MLP-ACF2 and 2MLP-ACF1?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003e2MLP-ACF2\u003c\/strong\u003e delivers \u003cstrong\u003eDC 5 V at 6 A\u003c\/strong\u003e. The \u003cstrong\u003e2MLP-ACF1\u003c\/strong\u003e delivers \u003cstrong\u003eDC 5 V at 3 A\u003c\/strong\u003e plus an auxiliary \u003cstrong\u003eDC 24 V at 0.6 A\u003c\/strong\u003e output. Choose ACF2 for higher 5 V current capacity; choose ACF1 if your application requires an auxiliary 24 V supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module operate on both 110 VAC and 220 VAC?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003e85–264 VAC\u003c\/strong\u003e input range allows direct connection to 110 VAC, 220 VAC, or 240 VAC industrial power without manual voltage selection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the input fuse replaceable?\u003c\/strong\u003e\u003cbr\u003eA: No, the module contains a \u003cstrong\u003ebuilt-in UL-standard slow-blow fuse\u003c\/strong\u003e that is not user-replaceable. If the fuse blows, replace the entire module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the RUN relay output indicate?\u003c\/strong\u003e\u003cbr\u003eA: The RUN relay closes when the output voltage is within specification, providing a \u003cstrong\u003e24 VDC @ 0.5 A\u003c\/strong\u003e signal suitable for status lamps, PLC inputs, or safety interlock circuits.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInstall the module into the \u003cstrong\u003epower supply slot\u003c\/strong\u003e of a MasterLogic-200 main or expansion base.\u003c\/li\u003e\n  \u003cli\u003eConnect \u003cstrong\u003eAC power (L, N, PE)\u003c\/strong\u003e to the input terminals using 0.75–2 mm² wire with RAV1.25-3.5 or RAV2-3.5 crimp terminals.\u003c\/li\u003e\n  \u003cli\u003eConnect the \u003cstrong\u003eground (PE) terminal\u003c\/strong\u003e to the cabinet earth bus for safety and electromagnetic compatibility.\u003c\/li\u003e\n  \u003cli\u003eWire the \u003cstrong\u003eRUN relay output\u003c\/strong\u003e to your status monitoring circuit if remote power supervision is required.\u003c\/li\u003e\n  \u003cli\u003eVerify the \u003cstrong\u003efront-panel LED\u003c\/strong\u003e illuminates to confirm normal output voltage before energizing I\/O modules.\u003c\/li\u003e\n  \u003cli\u003eEnsure the control cabinet provides adequate ventilation to maintain the module within its \u003cstrong\u003e0°C to +55°C\u003c\/strong\u003e operating range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Capacity:\u003c\/strong\u003e The 2MLP-ACF2 provides 6 A at 5 VDC. Calculate the total current draw of your CPU, I\/O, and communication modules to ensure the 6 A limit is not exceeded. For lighter loads, the \u003cstrong\u003e2MLP-ACF1\u003c\/strong\u003e (3 A) offers a cost-optimized alternative.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Environment:\u003c\/strong\u003e The 85–264 VAC range covers most global industrial voltages. If your plant uses DC input exclusively, consider the \u003cstrong\u003e2MLP-DC42-CC\u003c\/strong\u003e (DC 24 V input) instead.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e The 2MLP-ACF2 is a single power supply module. For redundant power architectures, use the \u003cstrong\u003e2MLR-AC12\u003c\/strong\u003e (110 VAC) or \u003cstrong\u003e2MLR-AC22\u003c\/strong\u003e (220 VAC) redundant power modules designed for MasterLogic-200R systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Ventilation:\u003c\/strong\u003e At full 6 A load, ensure the control cabinet has sufficient airflow or cooling fans to prevent thermal derating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53978173243576,"sku":"2MLP-ACF2","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/2MLP-ACF2_1__Co_a370a4dc-6398-45e1-bda8-a7bba4bd279e.png?v=1787628688","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-2mlp-acf2-free-voltage-ac-power-supply-module-85-264-vac-5-vdc-at-6-a","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}