{"product_id":"honeywell-900a01-0102-analog-input-module-8-point","title":"Honeywell 900A01-0102 Analog Input Module 8 Point","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900A01-0102\u003c\/strong\u003e is a \u003cstrong\u003eUniversal Analog Input Module\u003c\/strong\u003e providing \u003cstrong\u003e8 isolated channels\u003c\/strong\u003e for the Honeywell ControlEdge HC900 platform. This versatile module accepts multiple signal types including \u003cstrong\u003ethermocouples (TC), RTDs, voltage, current (4-20 mA), millivolt, and slidewire\u003c\/strong\u003e inputs, making it ideal for comprehensive process monitoring applications. With \u003cstrong\u003e16-bit A\/D resolution\u003c\/strong\u003e, \u003cstrong\u003e±0.1% accuracy\u003c\/strong\u003e, and \u003cstrong\u003egalvanic isolation\u003c\/strong\u003e per channel, it delivers precise, reliable measurement of temperature, pressure, flow, and level variables.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 Isolated Analog Inputs:\u003c\/strong\u003e Per-channel galvanic isolation for signal integrity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Signal Support:\u003c\/strong\u003e TC, RTD, voltage, current (4-20 mA), mV, slidewire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-Bit A\/D Resolution:\u003c\/strong\u003e High-precision digital conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e±0.1% Full-Scale Accuracy:\u003c\/strong\u003e Factory-calibrated precision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e400 VDC Point-to-Point Isolation:\u003c\/strong\u003e Prevents ground loops and noise\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swap Capable:\u003c\/strong\u003e Replace without system shutdown\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Volatile Calibration:\u003c\/strong\u003e Calibration data stored in module memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 900A01-0102\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Universal Analog Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ControlEdge HC900\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 8 (isolated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Types:\u003c\/strong\u003e Thermocouple (J, K, T, E, R, S, B, N), RTD (Pt100, Pt1000, etc.), Voltage (0-10V, ±10V, etc.), Current (4-20 mA, 0-20 mA), mV, Slidewire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e \u0026gt; 1 MΩ (voltage), 250 Ω (current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\/D Resolution:\u003c\/strong\u003e 16-bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.1% of full scale (at reference conditions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 400 VDC point-to-point, 1000 VDC to logic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 500 ms (per module)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan Time:\u003c\/strong\u003e 500 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 5V: 380 mA max; 24V: 40 mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e ~8.5W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 137 mm H × 35.6 mm W (5.4\" H × 1.4\" W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~210 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Chassis slot mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, UL508, TÜV, CSA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Insertion:\u003c\/strong\u003e Slide module into designated I\/O slot; secure with retention mechanism\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block:\u003c\/strong\u003e Use 900TEK (Euro style) or 900TBK (barrier style) terminal block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Wiring:\u003c\/strong\u003e Connect sensors per signal type:\n\u003cul\u003e\n\u003cli\u003eThermocouple: Connect + and - leads; use compensation cable\u003c\/li\u003e\n\u003cli\u003eRTD: Connect 2-wire, 3-wire, or 4-wire per configuration\u003c\/li\u003e\n\u003cli\u003e4-20 mA: Connect +24V, signal +, signal -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Connect cable shields to single-point ground\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Set channel types and ranges in ControlEdge Builder software\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 900A01-0102 and 900A01-0202?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; 900A01-0202 is a later revision with similar functionality. Both support universal analog inputs. Verify software compatibility when mixing revisions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can all 8 channels be configured differently?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; Yes. Each channel is independently configurable for any supported input type via ControlEdge Builder software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is HART protocol supported?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; The 900A01-0102 does not natively support HART. For HART-enabled analog inputs, consider the \u003cstrong\u003e900U01-0100\u003c\/strong\u003e Universal I\/O Module.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse 900A01-0102 when multiple analog signal types (TC, RTD, mA, V) are needed in one module\u003c\/li\u003e\n\u003cli\u003eFor high-density voltage\/current only (16 CH), use \u003cstrong\u003e900A16-0101\/0103\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eVerify sensor wiring requirements (2-wire vs. 3-wire RTD) before installation\u003c\/li\u003e\n\u003cli\u003eConsider \u003cstrong\u003e900U01-0100\u003c\/strong\u003e Universal I\/O for mixed AI\/AO\/DI\/DO applications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53827400401080,"sku":"900A01-0102","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/900A01-0102.png?v=1785223060","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-900a01-0102-analog-input-module-8-point","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}