{"product_id":"honeywell-900a16-0101-analog-input-hi-level-module","title":"Honeywell 900A16-0101 Analog Input Hi Level Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900A16-0101\u003c\/strong\u003e is a \u003cstrong\u003eHigh-Level Analog Input Module\u003c\/strong\u003e providing \u003cstrong\u003e16 isolated channels\u003c\/strong\u003e for voltage and current signal acquisition in the Honeywell ControlEdge HC900 system. Designed for high-density process monitoring, this module accepts \u003cstrong\u003e±10V voltage\u003c\/strong\u003e and \u003cstrong\u003e4-20 mA current\u003c\/strong\u003e inputs with \u003cstrong\u003e15-bit A\/D resolution\u003c\/strong\u003e and \u003cstrong\u003e±0.1% accuracy\u003c\/strong\u003e. Point-to-point galvanic isolation and solid-state switching ensure reliable operation in noisy industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Isolated Analog Inputs:\u003c\/strong\u003e High-density voltage and current acquisition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Level Signals:\u003c\/strong\u003e ±10V, 4-20 mA, 0-20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15-Bit A\/D Resolution:\u003c\/strong\u003e Precise digital conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e±0.1% Accuracy:\u003c\/strong\u003e Factory-calibrated precision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e400 VDC Point-to-Point Isolation:\u003c\/strong\u003e Prevents ground loops\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100 ms Update Rate:\u003c\/strong\u003e Fast analog-to-digital conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Sampling:\u003c\/strong\u003e Consistent scan rate regardless of module count\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 900A16-0101\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e High-Level Analog Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e ControlEdge HC900\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 16 (isolated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Types:\u003c\/strong\u003e Voltage (±10V, 0-10V, etc.), Current (4-20 mA, 0-20 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e \u0026gt; 1 MΩ (voltage), 250 Ω (current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\/D Resolution:\u003c\/strong\u003e 15-bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.1% of range (factory configured)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 400 VDC point-to-point; 1000 VDC to logic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Rejection:\u003c\/strong\u003e Series mode \u0026gt; 31 dB; Common mode \u0026gt; 90 dB at 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-Range Limit:\u003c\/strong\u003e ±10% for linear ranges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 100 ms (per module)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan Time:\u003c\/strong\u003e 100 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 5V: 75 mA max; 24V: 50 mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e ~2.2W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 137 mm H × 35.6 mm W (5.4\" H × 1.4\" W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~397 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Chassis slot mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, UL, TÜV, CSA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Insertion:\u003c\/strong\u003e Install in HC900 I\/O rack slot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block:\u003c\/strong\u003e Use 900TEK\/900TBK low-voltage terminal blocks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmitter Wiring:\u003c\/strong\u003e Connect 2-wire or 4-wire transmitters per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Single-point ground for shielded cables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Set voltage or current range per channel in ControlEdge Builder\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 900A16-0101 and 900A16-0103?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; 900A16-0103 is a later revision with enhanced specifications. Both are 16-channel high-level analog input modules. Verify software compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module measure thermocouples or RTDs?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; No. The 900A16 is for high-level voltage\/current signals only. For TC\/RTD inputs, use \u003cstrong\u003e900A01-0102\u003c\/strong\u003e Universal Analog Input Module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum source resistance for current inputs?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; The module presents a 250 Ω burden. Ensure transmitter output voltage is sufficient to drive 4-20 mA through this resistance plus wiring.\u003c\/p\u003e\n\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse 900A16-0101 for high-density voltage\/current monitoring (16 CH vs. 8 CH on 900A01)\u003c\/li\u003e\n\u003cli\u003eFor mixed signal types (TC, RTD, mA, V), use \u003cstrong\u003e900A01-0102\u003c\/strong\u003e instead\u003c\/li\u003e\n\u003cli\u003eVerify scan time requirements: 100 ms for 900A16 vs. 500 ms for 900A01\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53827401941176,"sku":"900A16-0101","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6132\/3704\/files\/900A16-0101_3_cad6df09-0129-4483-8119-f458b99acaab.png?v=1785223062","url":"https:\/\/www.globalpetroparts.com\/products\/honeywell-900a16-0101-analog-input-hi-level-module","provider":"Global Petro Parts Automation","version":"1.0","type":"link"}